4-5.
FLANGE BACK (f'F) CHECK/ADJUSTMENT
Equipment
• 1000 mm Collimator
• Flange Back Tester
• A-mount Attachment
• Flange Back Gauge (43.50mm)
1. Preparations
1) Perform "1. Preparations" of "4-3. OPTICAL AXIS CHECK/ADJUSTMENT".
4-5-1. Flange Back (f'F) Check
1) Calculate the flange back (f'F) of the checking lens using the following formula, and check that the specification of the Table 4-5-1 is
satisfied.
Flange back (f'F) of the checking lens = (SR flange back gauge) + (Number of short-pointer revolution) + (Reading of long-
pointer)
Specification
Focal-length
f'F (mm)
f (mm)
(Infinity position)
35
Table 4-5-1
2) When the flange back (f'F) of the checking lens is out of specification of the Table 4-5-1, perform "4-5-2. Flange Back (f'F)
Adjustment".
SAL35F14G (1.4/35G) (35mm F1.4G)
44.58 to 44.62