Download Print this page

Sony SAL35F14G Service Manual page 24

1.4/35g; 35mm f1.4g
Hide thumbs Also See for SAL35F14G:

Advertisement

HELP14
Anti-diffusion agent (A-20): J-6082-611-A
Adhesive bond (B-10):
1.
Apply anti-diffusion agent (A-20) to the indicated portion of inner barrel.
2.
After "4-2-2. Aperture Diameter Adjustment", apply the adhesive bond (B-10) in with of 10mm to all circumferences of portions
indicated in figure at inner barrel, aperture holding ring and aperture unit holding spring.
Apply the anti-diffusion agent (A-20) to
all circumference of indicated portion.
Apply the adhesive bond (B-10)
SAL35F14G (1.4/35G) (35mm F1.4G)
J-6082-612-A
Apply the anti-diffusion agent (A-20) to
all circumference of indicated portion.
Inner Barrel
Inner Barrel
Aperture Holding Ring
Apply the adhesive bond (B-10)
(width of 10mm to 3 locations)
G7
G8 G9 G10
3 Group Lens Block
Aperture Unit Holding Spring
Aperture Unit Holding Spring
G10 Stopper