Chapter 1
Hardware Features
Feature
chassis height
chassis width
chassis length
weight
bays
hard disk drives
CPU
power supply
system battery
motherboard chipset
memory
expansion slots
VGA
LAN
USB
Super I/O
BMC
BIOS
temperature
relative humidity
maximum vibration
maximum shock
altitude
other
Introduction
Description
1.66" (1U form factor)
16.8"
23"
27 lbs. (maximum)
four (4) ATA 100/133 hard disk drive bays, all ATA master channels in a RAID
configuration
unit ships with no (0) hard disk drives
Note:
You can install four (4) parallel ATA hard disk drives up to 300 GB in
capacity.
unit ships with one (1) Intel Pentium® 4 processor with a speed of 2.4 GHz
•
one (1) 250 W power supply
•
Volts : 100–240 VAC, 50–60 Hz
•
output hold up time : 20 ms minimum
•
maximum inrush current : under typical line conditions and over the entire system
ambient operating range, the inrush current may reach 30A per power supply for
10 ms or less
3.0-V lithium ion coin cell
Server Works north bridge and south bridge
ECC 512 MB registered DDR 266 MHz PC-2100 SDRAM using one half height
module (upgradeable to 1 GB modules)
one available 64bit/133MHz PCI-X slot
one available 64bit/33MHz PCI slot
both slots support full-height, half-length cards
onboard ATI Rage XL with 8 MB of video memory
dual 10/100/1000 BASE-T NICs with RJ45 Ethernet ports
dual USB 1.0 and 1.1
one (1) PS/2 mouse connector, one (1) PS/2 keyboard connector and one (1) serial port
embedded systems management circuitry that monitors the following:
•
–12V, +12V, CPU Vcore, LAN1_2, LAN2_5V, VDD_IMB, VGA2.5V, 3.3V,
5V, 1.5V, 3.3VSBY, 5VSBY, VBAT, A_VTT
•
System Temperature Detect, Adaptive FAN Speed Control, FAN Speed
Detection
•
CPU Temperature Detection
•
CPU VID code
The systems management circuitry works in conjunction with the AMI NAS 2.0
software.
AMI Server BIOS (Core 7)
operating : 50°F to 95°F at 10,000 feet above sea level, 50°F to 104°F at sea level
storage : –40°F to 149°F
operating : 20% to 80% (noncondensing)
storage : 5% to 95% (noncondensing)
operating : 0.25 G at 3 to 200 Hz for 15 minutes
storage : 0.50 G at 3 to 200 Hz for 15 minutes
operating : one shock pulse in the positive and negative x, y, and z axes (one pulse on
each side of the system) of 31 G for up to 2 ms
storage (non-operational) : six consecutively executed shock pulses in the positive and
negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 ms
operating : –16 to 3,048 m (–50 to 10,000 ft.)
storage : –16 to 10,600 m (–50 to 35,000 ft.)
hand tools are not required to replace internal chassis parts
Chapter One : Introduction
1