Diagnostics Using The Front Panel; Figure 4-1: Front Panel Status Leds - Alvarion BreezeACCESS LB System Manual

Alvarion breezeaccess breezeaccess lb wireless bridge: user guide
Hide thumbs Also See for BreezeACCESS LB:
Table of Contents

Advertisement

Chapter 4 - Diagnostics and Troubleshooting

Diagnostics Using the Front Panel

The front panel of the BreezeACCESS LB NI-01 Indoor unit comprises
three sets of status LEDs, grouped under the headings System, Wireless
and Ethernet, to help with first level diagnoses of problems encountered
with the unit.

Figure 4-1: Front Panel Status LEDs

Depressing the button for less than five (5) seconds will activate a "short
reset", which is equivalent to turning the LB NI-01 Indoor unit off and
on. Statistical values are reset, and the currently loaded software /
firmware will be retained. Note that a short reset may be accomplished
remotely by clicking on the Save Configuration button on the System
Configuration screen.
Depressing the Reset button for more than five (5) seconds executes a
"long reset". A long reset reloads the factory default configuration
settings such as IP Address, Subnet Mask, Channel, Device Name, etc.
and restarts the system. The software version that existed in the system
before the long reset is retained. An example of when a long reset will
help is in the event that a password or IP address is forgotten. The long
reset function will simply restore the system back to its original factory
default settings. A long reset is confirmed by the Wireless Link LED
flashing three times, followed by the LED power-up sequence: