The Indoor Unit at a Glance
The front panel of the LB NI-01 Indoor unit includes a LAN interface
and three main status indicators: System, Wireless, and Ethernet. The
rear of the LB NI-01 Indoor unit includes the power cord connector and
an F-Type female connector for the IF cable.
At power up, an LED power-up sequence occurs as follows:
All four Ethernet LEDs light for one second, then individual Ethernet
LEDs blink twice in the following order: 100, FD, Col, Link. The Fault
LED lights for approximately four seconds, and then turns off. The two
Wireless LEDs remain off for approximately five seconds, and then
resume their normal state.
For a detailed description of the status indicators on the front panel, see
Diagnostics Using the Front
System Status Indicators
The System portion of the front panel features a recessed reset switch
and two LEDs (Pwr and Fault), as shown in the figure below.
Figure 2-1: Front Panel - System
Reset – depressing the "Reset" button recessed in the front panel can
hard reset the system. The reset button is used to reactivate the
BreezeACCESS LB unit in the event that it is functioning improperly or
is in a state of suspension.
Pwr – The "Pwr" LED lights solid and green when the AC power is
properly applied to the LB NI-01 Indoor unit. In the event of internal
power supply failure, if the cord is disconnected, or if the fuse is blown,
the "Pwr" light will not illuminate
Fault – The "Fault" LED lights solid red when a serious fault is detected
within the system
Panel, on page 4-2.