Fill the Fluid Supply

1. Follow the
Fluid Voltage Discharge and
Grounding Procedure, page
2. Follow the
Pressure Relief Procedure, page
3. Open the isolated enclosure door.
4. Remove the pail cover from the pail, holding a rag
over the suction tube strainer to prevent any fluid
from dripping into the isolated enclosure. Place
the cover and suction tube outside the enclosure.
5. Remove the supply pail from the enclosure.
Be sure to wipe up all fluid spills in the isolated
enclosure. Fluid can create a conductive path
and cause the system to short out.
3A2497C
25.
NOTICE
6. Clean up any fluid spills in the enclosure, using
a soft cloth and a non-flammable, compatible
solvent.
7. Fill the supply pail with fluid and return it to the
enclosure. Clean up any spills.
26.
8. Reinstall the pail cover, holding a rag over the
suction tube strainer to prevent fluid spills while
you place the pump suction tube in the pail.
9. Close the isolated enclosure door and fasten
securely with the T-handle locking screw.
Operation
27