3. The Rosemount 702 enclosure may be made of aluminum alloy and given
a protective polyurethane paint finish; however, care should be taken to
protect it from impact or abrasion if located in a Zone 0 area.
7.9.2
IY IECEx Intrinsic Safety for Zone 2
Certificate: IECEx BAS 12.0082X
Standards: IEC 60079-0: 2011, IEC 60079-11: 2011
Markings:
Sensor terminal parameters (input)
U
= 6.6 V
O
I
= 13.4 mA
O
P
= 21.8 mW
O
C
= 10.9 µF
O
L
= 25 µH
O
Special Conditions for Safe Use (X):
1. The surface resistivity of the antenna is greater than 1 GΩ. To avoid
electrostatic charge build-up, it must not be rubbed or cleaned with
solvents or dry cloth.
2. The Rosemount 701PBKKF Power Module may be replaced in a hazardous
area. The power modules have a surface resistivity greater than 1 GΩ and
must be properly installed I the wireless device enclosure. Care must be
taken during transportation to and from the point of installation to
prevent electrostatic charge build-up.
3. The Rosemount 702 enclosure may be made of aluminum alloy and given
a protective polyurethane paint finish; however, care should be taken to
protect it from impact or abrasion if located in a Zone 0 area.
7.10
China
7.10.1 I3 China Intrinsic Safety
Certificate: GYJ13.1238X
Standards: GB3836.1-2010, GB3836.4-2010, GB3836.20-2010
Markings:
Quick Start Guide
Ex nA IIC T4 Gc, T4(-40 °C ≤ T
T5(-40 °C ≤ T
≤ +40 °C)
a
(option 32, 61): Ex ia IIC T4/T5 Ga, T4(-60 ≤ T
≤ T
≤ 40 °C)
a
(option 32, 42): Ex ic IIC T4/T5 Gc, T4(-60 ≤ T
≤ T
≤ 40 °C)
a
≤ +70 °C); Ex nA IIC T5 Gc,
a
Switch terminal parameters
(output)
U
= 26 V
i
I
= 100 mA
i
P
= 0.65 W
i
N/A
N/A
≤ 70 °C)/T5(-60
a
≤ 70 °C)/T5(-60
a