Download Print this page

Emerson Rosemount 702 Quick Start Manual page 46

Wireless discrete transmitter
Hide thumbs Also See for Rosemount 702:

Advertisement

Quick Start Guide
Special Conditions for Safe Use (X):
1. The surface resistivity of the antenna is greater than 1 GΩ. To avoid
electrostatic charge build-up, it must not be rubbed or cleaned with
solvents or dry cloth.
2. The Rosemount 701PB Power Module may be replaced in a hazardous
area. The power module has surface resistivity greater than 1 GΩ and
must be properly installed in the wireless device enclosure. Care must be
taken during transportation to and from the point of installation to
prevent electrostatic charge build-up.
7.9
International
7.9.1
I7 IECEx Intrinsic Safety
Certificate: IECEx BAS 07.0082X
Standards: IEC 60079-0: 2011, IEC 60079-11: 2011
Markings:
Sensor terminal parameters (option code 32)
U
= 6.51 V
O
I
= 13.37 mA
O
P
= 21.76 mW
O
C
= 0.216 µF
i
C
= 21.78 µF
O IIC
C
= 549.78 µF
O IIB
C
= 1000 µF
O IIA
L
= 0
i
L
= 200 mH
O IIC
L
= 800 mH
O IIB
L
= 1000 mH
O IIA
Special Conditions for Safe Use (X):
1. The surface resistivity of the antenna is greater than 1 GΩ. To avoid
electrostatic charge build-up, it must not be rubbed or cleaned with
solvents or dry cloth.
2. The Rosemount 701PBKKF Power Module may be replaced in a hazardous
area. The power modules have a surface resistivity greater than 1GΩ and
must be properly installed I the wireless device enclosure. Care must be
taken during transportation to and from the point of installation to
prevent electrostatic charge build-up.
46
Ex ia IIC T4 Ga, T4(-40 °C ≤ T
T5(-40 °C ≤ T
≤ +40 °C)
a
≤ +70 °C); Ex ia IIC T5 Ga,
a
Fuel sensor terminal parameters (option
code 61)
U
= 7.8 V
O
I
= 92 mA
O
P
= 180 mW
O
C
= 10 nF
i
C
= 9.2 µF
O IIC
C
= 129 µF
O IIB
C
= 1000 µF
O IIA
L
= 0
i
L
= 4.2 mH
O IIC
L
= 16.8 mH
O IIB
L
= 33.6 mH
O IIA
Rosemount 702 Wireless Discrete Transmitter
April 2018

Advertisement

loading