Mitsubishi AJ65BT-64RD3 User Manual page 114

Pt 100 temperature input module
Hide thumbs Also See for AJ65BT-64RD3:
Table of Contents

Advertisement

www.plcworld.cn
5 PROGRAMMING
Procedure Execution Condition
Initial data processing request flag (RX18) turns on
Initial data processing request flag (RX18) turns off
Initial data setting completion flag (RX19) turns on
(2) Initial setting by remote device station initialization procedure
registration
(a) Setting the target station number
Set the station number to which initial setting will be made.
Set the target station number to "1".
(b) Setting the procedure registration
When the initial data processing request flag (RX18) turns on and the
remote device station initialization procedure registration (SB0D) is set, the
following data are registered to the AJ65SBT-64AD.
A/D conversion enable/prohibit specification: channels 1, 2: enable
(RWw0: 0003
Input range setting : channel 1: 0 to 5V
(RWw1: 51
Moving average processing count setting: channel 2: 16 times
(RWw5: 10
CH.1 moving average processing specifying flag: sampling processing
(RY00:OFF)
CH.2 moving average processing specifying flag: moving average processing
(RY01:ON)
Initial data processing completion flag (RY18) is turned on.
Initial data setting request flag (RY19) is turned on.
Initial data processing completion flag (RY18) is turned off.
Initial data setting request flag (RY19) is turned off.
(c) Setting results
The setting results are shown below.
Execution
)
H
: channel 2: user range setting 1
)
H
)
H
5 - 5