Inner Enamel Panel Installation

Black Enamel Panels — Handling Instructions
Black Enamel panels must be inspected for scratches and dimples prior to installation.
All claims to be recorded at this time.
Claims for damage after installation will not receive consideration.
Black Enamel panels will discolor a little during normal operation. This is normal and should not be considered a defect.
*
All hand and finger marks MUST be cleaned off with a soft cloth. Use an ammonia based cleaner (ie. glass cleaner) to remove any
fingerprints before applying heat to the unit.
Failure to do this will result in burn stain on panels which you will be unable to remove.
ACB60 INNER ENAMEL PANEL
*Not protected by product warranty.
INSTALLATION
ACB60E - 7 outer panels and 8 inner panels.
Turn off gas and power to unit and allow to cool to room tempera-
ture. Remove the safety glass and firebox glass — see manual for
instructions.
1. Install 5 inner base panels as shown.
2. On back of firebox wall--install 6 screws (loosely) in locations shown
below. Install 3 back panels--hang panels on installed screws through
keyhole opening.
3. Reinstall firebox glass - see instructions in manual.
ACB60E OUTER PANELS
1. Install outer side panel as shown below.
CITY SERIES
2. Install glass stopper (if desired) by sliding down the outside of
the outer side panel.
3. Slide backwall outer panel behind glass stopper bracket (if installed).
4. Install front end panel-place on unit as shown below.
installation