Horizontal Terminations - Rigid Pipe 127 Mm X 203 Mm - Regency City ACB60ENG Owners & Installation Manual

Direct vent
Table of Contents

Advertisement

Horizontal Terminations - Rigid Pipe 127 mm x 203 mm

The minimum components required for a basic horizontal
termination are:
1
Horizontal Termination Cap
1
Rigid Pipe Adaptor (770-994)
1
Wall Thimble
1
Length of pipe to suit wall thickness
(see chart)
Wall thickness is measured from the back standoffs to the inside
mounting surface of termination cap. For siding other than vinyl
furring strips may be used, instead of the vinyl siding standoff, to
create a level surface to mount the vent terminal. The Terminal
must not be recessed into siding. Measure the wall thickness
including furring strips.
If a Vinyl Siding Standoff is required (it must be used with vinyl
siding), measure to outside surface of wall without siding and
add 51 mm.
Flat Wall Installation
Wall Thickness
102 mm - 140 mm
178 mm - 216 mm
246 mm - 292 mm
229 mm - 368 mm
381 mm - 597 mm
WARNING:
Do not combine venting components from
different venting systems.
However use of the the AstroCap
Riser is acceptable with all systems.
Vent Length Required
152 mm
229 mm
305 mm
279 mm - 371 mm Adj. Pipe
432 mm - 610 mm Adj. Pipe
and FPI
TM
*Unit is not exactly as shown.
installation
Vinyl Siding
Standoff (Optional)
Wall Thimble
Adj.Pipe Length
90 Elbow
o
Pipe Length
Rigid Pipe Adapter
When using Rigid Vent other than
Simpson Dura-Vent, 3 screws must be
used to secure rigid pipe to adaptor.
City Series ACB60E | 57
Horizontal
Termination Cap

Advertisement

Table of Contents
loading

Table of Contents