Clearances (3-sided)

The clearances listed below are minimum distances unless otherwise stated.
A major cause of chimney related fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this
fireplace and vent system be installed only in accordance with these instructions.
Clearance
A1: Mantel Height (min.)
A: From Floor (min.)
B: Sidewall (on one side) min.
C: Enclosure Width (min.)
D: Mantel Depth (max.)
E: Alcove Width
F: Alcove Depth
G: Convection Air Outlet Opening Offset
(min.)
H: Convection Air Outlet
I Enclosure Depth (min.)
J: Opening Height
K: To Ceiling (min.) all 3 sides
L: Chase Enclosure (min.)
M:Clearance to Sprinkler Head (min.)
Hearth
** See mantel clearances chart in the manual.
B
Dimension
**
260 mm
149 mm
1810 mm
**
3035 mm
889 mm
50 mm
1161 square centimeters
516 mm
457 mm
44 mm
2064 mm
914 mm
0"
E
F
Alcove
Measured From:
Top of Fireplace Opening
Bottom of Fireplace Opening
Side of Fireplace Opening
Minimum inside dimensions
Sidewall to Sidewall (Minimum)
Front to Unit (Maximum)
Max. offset from top of chase enclosure
Minimum inside dimensions
Bottom/Top of Fireplace Opening
To Top of Ceiling
From base of unit/floor to top of enclosure
Perpendicular from chase grill
No hearth required
The top, back and sides of the fireplace are defined by
standoffs. The metal ends of the standoff may NOT be
if these clearances (air space) to combustible materials are not
adhered to. It is of greatest importance that this fireplace and vent
system be installed only in accordance with these instructions.
Flue Clearances to Combustibles
Horizontal - Top
Horizontal - Side
Horizontal - Bottom
Vertical
Passing through wall/
floor/ceiling - when
firestop is used.
Note: This appliance uses 127 mm x 203 mm
venting.
M
L
Chase grill
Side view
The HeatWave Duct Kit has differ-
ent clearance and framing require-
ments, check the HeatWave manual
for details.
Caution Requirements
recessed into combustible construction.
WARNING
Fire hazard is an extreme risk
City Series ACB60E | 29
installation
76 mm
51 mm
51 mm
51 mm
38 mm
Sprinkler