Vertical Flue Extension Kit
Part #946-769

Vertical Flue Extension Kit (Approved Models) (Part # 946-769)

6.1 m flex pipe extension
VERTICAL FLUE EXTENSION KIT (APPROVED MODELS)
Used in conjunction with the 946-772 Vertical Flex Kit for vertical
installations.
(PART # 946-756)
1. Stretch out both inner 127 mm and outer 203 mm pipe up to a
VERTICAL FLUE EXTENSION KIT (APPROVED MODELS)
maximum of 6.1 m.
The inner and outer pipes may be cut if only a
(PART # 946-756)
short length is required.
2. Install spring spacers around 127 mm inner pipe as shown. Slide
outer flex pipe over and all the way down the 127 mm pipe.
3. Apply a bead of Mill Pac around the perimeter of the 127 mm
inner collar of the flex adapter and slip the 127 mm inner flex
pipe from the Vertical termination kit over the flex adapter ensur-
ing that the inner flex pipe overlaps the collar by at least 35 mm.
Fasten with 3 screws.
4. Apply a bead of Mill Pac around the perimeter of the 203 mm
outer collar of the flue adapter and slip it over the 203 mm outer
flex pipe from the vertical termination kit ensuring that the outer
flex pipe overlaps the collar by at least 35 mm. Fasten with the 3
screws.
5. Repeat steps to secure the other end of the flex adapter using
the flex kit.
6. See vertical vent installation instructions for installation of the
complete vent system.
If an offset is necessary in the attic or floor joists
it is important to sup-port the vent pipe every 0.91
m to avoid excessive stress and sagging of the
vent pipe. Wall straps are provided (3 in total) for
this purpose.
All round/plumbers strapping may also be used if
further supports are required.
Ceiling Firestop/Firestop Spacer
VERTICAL FLUE EXTENSION KIT (APPROVED MODELS)
Ceiling Firestop / Firestop Spacer (Part 946-770)
Part #946-770
(PART # 946-756)
VERTICAL FLUE EXTENSION KIT (APPROVED MODELS)
Used in conjunction with the 946-772 Vertical Flex Kit and 946-769
Vertical Flex Extension Kit.
(PART # 946-756)
A ceiling firestop/firestop spacer must be installed when passing
through each floor or ceiling level.
Steps to install the ceiling firestop/firestop spacer in a flat ceiling or
floor joist:
1. Cut a 279 mm square hole.
2. Frame the hole as show in Diagram 1.
3. Install the ceiling firestop.
4. Slide the top attic insulation spacer onto the top of the attic insu-
lation shield/firestop - See Diagram 1a.
5. Secure with 4 screws/nails.
Firestops can be purchased separately if more than one is required.
The ceiling firestop/firestop spacer may be cut
919-696
down to size if it is too high for the application.
920-381
920-328
920-337
| City Series ACB60E
64
920-328
920-337
127 mm inner pipe - 6.1 m
127 mm inner pipe
127 mm inner pipe
6.1m
10 spring spacers
203 mm outer
flex pipe 6.10 m
203 mm
outer flex pipe
6.1m
203 mm
outer flex pipe
6.1m
279 mm
square hole
framing
127 mm inner pipe
127 mm inner pipe
6.1m
Ceiling firestop
10 spring spacers
Diagram 1
1
203 mm
Page 1
outer flex pipe
6.1m
203 mm
1
1
outer flex pipe
6.1m
1
1
10 spring spacers
6.1m
Flex adaptor
10 spring spacers
3 wall straps
flex adaptor
flex adaptor
3 wall straps
3 wall straps
Termination Cap
Storm Collar
6.1m
Firestop spacer
Flashing
Termination Cap
to prevent debris
from falling
10 spring spacers
into the ceiling
Storm Collar
firestop
Flashing
Roof support
Roof support
flex adaptor
Ceiling firestop
Enclosure
flex adaptor
3 wall straps
Ceiling firestop
3 wall straps
Diagram 1a
06.11.18
03.10.21
10.05.20
10.05.20
10.05.20
10.05.20

Advertisement

Table of Contents
loading

Table of Contents