Vertical Terminations - Rigid/Flex Pipe 127 Mm X 203 Mm - Regency City ACB60ENG Owners & Installation Manual

Direct vent
Table of Contents

Advertisement

Vertical Terminations - Rigid/Flex Pipe 127 mm x 203 mm

The minimum components required for a basic vertical termination are:
1
Vertical Termination Cap
Rigid Pipe Adaptor (Dura Vent Only)
1
1
Lengths of pipe to adequately penetrate roof.
1
Flashing (as required per AS/NZS 5601-2013, to be supplied
by installer.)
Wall thickness is measured from the back standoffs to the inside
mounting surface of the termination cap. For siding other than vinyl,
furring strips may be used instead of the vinyl siding standoff to create
a level surface to mount the vent terminal. The terrminal must
not be recessed into the wall cladding. Measure the wall thickness
including the wall cladding.
Roof Pitch
Meters
flat to 7/12
over 7/12 to 8/12
over 8/12 to 9/12
over 9/12 to 10/12
over 10/12 to 11/12
over 11/12 to 12/12
over 12/12 to 14/12
over 14/12 to 16/12
over 16/12 to 18/12
over 18/12 to 20/12
over 20/12 to 21/12
WARNING:
Do not combine venting components from different venting systems.
However use of the the AstroCap
0.61
0.61
0.61
0.76
0.99
1.22
1.52
1.83
2.13
2.29
2.44
and FPI Riser is acceptable with all systems.
TM
High Wind Cap
Flashing (not supplied)
Pipe Length
*Unit is not exactly as shown.
When using Rigid Vent other than
Simpson Dura-Vent, 3 screws must be
used to secure rigid pipe to adaptor.
installation
Rigid Pipe Adapter
(Use only with
Simpson Dura Vent)
City Series ACB60E | 59