ESAB B Series Installation, Operation And Maintenance Manual page 60

Precision plasmarc system
Table of Contents

Advertisement

ð
ð
CUP SHIELD
INSULATOR SHIELD
w/RETAINER
RETAINER w/O-RING
P/N 22531
P/N 21712
MATERIAL
RISE
THICKNESS PIERCE
ON
DELAY PIERCE
(MM)
(IN)
(Sec.)
(Sec.)
4
.187
.3
.1
6
.250
.4
.1
10
.375
.5
.1
13
.500
.6
.1
NOTES:
4 Hole Baffle - *Set flow reading with valves.
STAINLESS STEEL
AMPERAGE:
PLASMA GAS:
SHIELD GAS:
SHIELD MIX GAS:
NOZZLE "D"
SHIELD CUP
INSULATOR
P/N 21543
P/N 22010
ð
ð
ð
NOZZLE RETAINER/
DIFFUSER
(SEE NOTES)
P/N 22007
SET-UP PARAMETERS*
PLASMA
PLASMA
START
CUT
(FLOW READING) (FLOW READING)
70
100
70
100
70
100
70
100
† CUT & ALT mix in flow control. Pilot Arc - high. Float - center of ball.
11/30/99
70
NITROGEN
NITROGEN
METHANE
SWIRL BAFFLE
4 HOLE
(SEE NOTES)
P/N 21692
ð
ð
ð
ELECTRODE
NOTES:
P/N 21539
SHIELD
(FLOW READING)
PRE
CUT
ALT
60
65
5
60
65
5
60
65
5
60
70
5
PROCESS DATA
PRESSURE:125 PSI/8.6 BAR
PRESSURE:125 PSI/8.6 BAR
PRESSURE:100 PSI/6.9 BAR
PT-24 TORCH
1. Assemble swirl baffle into nozzle first.
2. To prevent leakage between the nozzle and nozzle retainer,
moisten the corner of a clean, dry, lint-free cloth with a very
small amount of Krytox
®
grease P/N73585064. Wipe the
inner surface of the nozzle retainer that comes in contact with
the nozzle. Use care to apply a very thin film to ensure a
proper seal.
3. Use tool (P/N 21765) supplied with torch to remove or install
nozzle, electrode and water baffle.
TRAVEL SPEED
ARC
VOLTAGE
(MM/MIN)
(IPM)
138
1778
70
150
1143
45
170
762
30
179
609
24
SS70NM