ESAB B Series Installation, Operation And Maintenance Manual page 45

Precision plasmarc system
Table of Contents

Advertisement

ð
ð
CUP SHIELD
INSULATOR SHIELD
w/RETAINER
RETAINER w/O-RING
P/N 22531
P/N 21712
MATERIAL
RISE
THICKNESS PIERCE
ON
DELAY PIERCE
(MM)
(IN)
(Sec.)
(Sec.)
0.9
20 GA
0
0
1.3
18 GA
0
0
1.5
16 GA
0
0
1.9
14 GA
.1
0
2.7
12 GA
.1
0
3.4
10 GA
.1
0
NOTES:
2 Hole Baffle - *Set flow reading with valves.
CARBON STEEL
AMPERAGE:
PLASMA GAS:
SHIELD GAS:
ALT. GAS:
SHIELD CUP
NOZZLE "A"
INSULATOR
P/N 22010
P/N 21540
ð
ð
ð
NOZZLE RETAINER/
DIFFUSER
(SEE NOTES)
P/N 22007
SET-UP PARAMETERS*
PLASMA
PLASMA
START
CUT
(FLOW READING) (FLOW READING)
20
11
20
11
20
11
20
11
20
11
20
11
† CUT & ALT mix in flow control. Pilot Arc - low. Float - center of ball.
11/30/99
16
OXYGEN
NITROGEN
OXYGEN
SWIRL BAFFLE
2 HOLE
(SEE NOTES)
P/N 21852
ð
ð
ð
NOTES:
ELECTRODE
P/N 21539
SHIELD
(FLOW READING)
VOLTAGE
PRE
CUT
ALT
50
0
5
50
0
5
50
0
5
50
0
5
50
0
5
50
0
5
PROCESS DATA
PRESSURE:125 PSI/8.6 BAR
PRESSURE:125 PSI/8.6 BAR
PRESSURE:125 PSI/8.6 BAR
PT-24 TORCH
1. Assemble swirl baffle into nozzle first.
2. To prevent leakage between the nozzle and nozzle retainer,
moisten the corner of a clean, dry, lint-free cloth with a very
small amount of Krytox
®
grease P/N73585064. Wipe the
inner surface of the nozzle retainer that comes in contact with
the nozzle. Use care to apply a very thin film to ensure a
proper seal.
3. Use tool (P/N 21765) supplied with torch to remove or install
nozzle, electrode and water baffle.
TRAVEL SPEED
ARC
(MM/MIN)
(IPM)
114
2540
100
117
2159
85
118
1778
70
123
1270
50
124
1016
40
129
914
36
CB15