ESAB B Series Installation, Operation And Maintenance Manual page 51

Precision plasmarc system
Table of Contents

Advertisement

ð
ð
CUP SHIELD
INSULATOR SHIELD
w/RETAINER
RETAINER w/O-RING
P/N 22531
P/N 21712
MATERIAL
RISE
THICKNESS PIERCE
ON
DELAY PIERCE
(MM)
(IN)
(Sec.)
(Sec.)
3
.125
0
0
4
.187
0
0
6
.250
.1
.1
10
.375
.2
.1
NOTES:
4 Hole Baffle - *Set flow reading with valves.
STAINLESS STEEL
11/30/99
AMPERAGE:
PLASMA GAS:
SHIELD GAS:
SHIELD MIX GAS:
NOZZLE "C"
SHIELD CUP
INSULATOR
P/N 21542
P/N 22010
ð
ð
ð
NOZZLE RETAINER/
DIFFUSER
(SEE NOTES)
P/N 22007
SET-UP PARAMETERS*
PLASMA
PLASMA
START
CUT
(FLOW READING) (FLOW READING)
60
95
60
95
60
95
60
95
† CUT & ALT mix in flow control. Pilot Arc - high. Float - center of ball.
50
AIR
AIR
AIR
SWIRL BAFFLE
3 HOLE
(SEE NOTES)
P/N 21536
ð
ð
ð
ELECTRODE
NOTES:
P/N 21539
SHIELD
ARC
(FLOW READING)
VOLTAGE
PRE
CUT
ALT
45
55
0
134
45
35
0
140
45
35
0
145
45
35
0
155
PROCESS DATA
PRESSURE:125 PSI/8.6 BAR
PRESSURE:125 PSI/8.6 BAR
PRESSURE:125 PSI/8.6 BAR
PT-24 TORCH
1. Assemble swirl baffle into nozzle first.
2. To prevent leakage between the nozzle and nozzle retainer,
moisten the corner of a clean, dry, lint-free cloth with a very
small amount of Krytox
®
grease P/N73585064. Wipe the
inner surface of the nozzle retainer that comes in contact with
the nozzle. Use care to apply a very thin film to ensure a
proper seal.
3. Use tool (P/N 21765) supplied with torch to remove or install
nozzle, electrode and water baffle.
TRAVEL SPEED
(MM/MIN)
(IPM)
2286
90
1524
60
1016
40
558
22
SS50A

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pt-24

Table of Contents