ESAB B Series Installation, Operation And Maintenance Manual page 46

Precision plasmarc system
Table of Contents

Advertisement

ð
ð
CUP SHIELD
INSULATOR SHIELD
w/RETAINER
RETAINER w/O-RING
P/N 22531
P/N 21712
MATERIAL
RISE
THICKNESS PIERCE
ON
DELAY PIERCE
(MM)
(IN)
(Sec.)
(Sec.)
1.9
14 GA
0
0
3
.125
0
0
3.2
.135
0
0
4
.187
.1
.1
6
.250
.2
.1
NOTES:
3 Hole Baffle - *Set flow reading with valves.
CARBON STEEL
11/30/99
AMPERAGE:
PLASMA GAS:
SHIELD GAS:
SHIELD MIX GAS:
NOZZLE "B"
SHIELD CUP
INSULATOR
P/N 21541
P/N 22010
ð
ð
ð
NOZZLE RETAINER/
DIFFUSER
(SEE NOTES)
P/N 22007
SET-UP PARAMETERS*
PLASMA
PLASMA
START
CUT
(FLOW READING) (FLOW READING)
38
15
38
15
38
15
38
15
38
15
† CUT & ALT mix in flow control. Pilot Arc - low. Float - center of ball.
35
OXYGEN
NITROGEN
OXYGEN
SWIRL BAFFLE
3 HOLE
(SEE NOTES)
P/N 21536
ð
ð
ð
ELECTRODE
NOTES:
P/N 21539
SHIELD
ARC
(FLOW READING)
VOLTAGE
PRE
CUT
ALT
50
0
5
113
50
0
10
119
50
0
10
120
50
0
10
122
50
0
10
124
PROCESS DATA
PRESSURE:125 PSI/8.6 BAR
PRESSURE:125 PSI/8.6 BAR
PRESSURE:125 PSI/8.6 BAR
PT-24 TORCH
1. Assemble swirl baffle into nozzle first.
2. To prevent leakage between the nozzle and nozzle retainer,
moisten the corner of a clean, dry, lint-free cloth with a very
small amount of Krytox
®
grease P/N73585064. Wipe the
inner surface of the nozzle retainer that comes in contact with
the nozzle. Use care to apply a very thin film to ensure a
proper seal.
3. Use tool (P/N 21765) supplied with torch to remove or install
nozzle, electrode and water baffle.
TRAVEL SPEED
(MM/MIN)
(IPM)
2032
80
1397
55
1320
52
1016
40
889
35
CB30