ESAB B Series Installation, Operation And Maintenance Manual page 25

Precision plasmarc system
Table of Contents

Advertisement

SECTION 2
Type
Pressure
Flow
Purity Required
Recommend Liquid Cylinder
Service Regulators
Recommended Cylinder 2-Stage
Regulators
Recommended Heavy-Duty
Hi-FIow Station or Pipeline
Regulators
Recommended High-Capacity
Station or Pipeline Regulators
Type
Pressure
Flow
Purity Required
Type
Pressure
Flow
Purity Required
Type
Rating
Dimensions:
Table 2-3. Technical Specifications
(Plasma Gas)
O
, N
, Air
2
2
125 psig (8.6 bar)
100 cfh (47 I/min) max (varies with application)
O
-99.8%,N
2
2
Oxygen: R-76-150-540LC (P/N 19777)
Inert Gas: R-76-150-580LC (P/N 19977)
Oxygen: R-77-150-540 (P/N 998337)
Hydrogen, Methane: R-77-150-350 (P/N 998342)
Nitrogen: R-77-150-580 (P/N 998344)
Industrial Air: R-77-150-590 (P/N 998348)
Oxygen: R-76-150-024 (P/N 19151)
Non-Corrosive, Non-Toxic Industrial Gas:
R-6703 (P/N 22236)
Table 2-4.Technical Specifications
(Starting Gas)
N
, Air
2
125 psig (8.6 bar)
60 cfh (28 I/min) max (varies with application)
99.995%, Dry, clean, free of oil and matter
Table 2-5. Technical Specifications
(Secondary Gas)
N
O
H-35, Methane
2
2
100 psig (6.9 bar) H-35, Methane
125 psig (8.6 bar) N
60 cfh (28 I/min) max (varies with application)
N
-99.995%; O
2
Table 2-6.Technical Specifications
(PT-24 Torch)
Water-Cooled, Dual Gas
100 amps @ 100% duty cycle
See Figure 8-9
21
-99.995%, Air-clean, dry, oil-free
, O
, Air
2
2
-99.8%, H-35, Methane-99.8%
2
DESCRIPTION

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pt-24