Procedure
1. Start programming by pressing the MODE key longer than 2 seconds until the
2. Also press the RESET / TEST key longer than 2 seconds until the
3. Release the MODE and RESET / TEST keys.
4. Switch the mode by pressing the MODE key briefly. The SOFT TORQUE LED switches
5. Terminate programming mode by pressing the RESET / TEST key for longer than
Further parameterization options
SIRIUS 3RW52 Soft Starter
Equipment Manual, 04/2020, A5E35630451002A/RS-AE/005
STATE / OVERLOAD LED flickers green.
Press and hold the MODE key.
LED STATE / OVERLOAD illuminates red.
The set state of ON / RUN relay output is displayed on the SOFT TORQUE LED:
SOFT TORQUE LED
Flashes green
Flickers green
between flickering green and flashing green.
You can switch between the modes at the output as often as you want.
Note
If you do not press a key in the programming mode for longer than 10 seconds, the
3RW52 soft starter automatically terminates the programming mode.
1 second until the STATE / OVERLOAD LED no longer shines red.
3RW5 HMI High Feature (accessory)
Menu: "Parameters > Soft Starter > ON / RUN relay output"
Procedure in chapter Parameterize the response to bus errors and output 13, 14
(ON / RUN) (Page 108)
6.7 Parameterize output 13, 14 (output signal ON or RUN)
Parameter assignment
Signal set at output 13, 14
ON (factory setting)
RUN
107