Availability Of Process Connections - Emerson Rosemount 5408 Reference Manual

Level transmitters, non-contacting radar with hart protocol
Hide thumbs Also See for Rosemount 5408:
Table of Contents

Advertisement

Reference Manual
00809-0100-4408
(1)
The Rosemount 5408:SIS has two operational modes: Safety (SIS) and Control/Monitoring. Safety (SIS) mode must be
set when used in Safety Instrumented Systems. Control/Monitoring mode is intended for use in a Basic Process Control
System (BPCS).
(2)
Solids level measurement is only available when operating in Control/Monitoring mode.
(3)
G½ thread form is not available with hazardous locations approvals.
(4)
Not available with performance class code A (ultra accuracy).
(5)
Type A flat face for EN 1092-1 flanges.
(6)
Type B1 raised face for EN 1092-1 flanges.
(7)
For applications where saturated steam may occur, consult factory.
(8)
Pressure limit is derated for process temperatures above 100 °F (38 °C), see
(9)
Refer to
Figure A-6
for pressure/temperature ratings of Tri-Clamp connection.
(10)
Option code PC1 is for cone antennas only, and requires matching flange and antenna sizes. Note that all parabolic
antennas come with an integrated air purge connection.
(11)
A minimum gasket thickness of 0.125 in. (3.2 mm) is required for flanges with protective plate design.
(12)
The standard alarm setting is high.
(13)
Only applies to flanged process connections with welded construction or protective plate design; only applicable to
cone antennas (see
Table A-13
(14)
Flanged process connections with protective plate design are only available with ASME IX (option code AW).
(15)
Not available with EN1092-1 or JIS B2220 flanges, neither for ASME B16.5 flanges in materials of construction code M.
(16)
Hydrostatic testing is only available for cone antennas and process seal antennas with flanged process connections.
(17)
Certificate includes all pressure retaining and wetted parts.
(18)
Only available for process seal antennas with Tri-Clamp connection.
(19)
Applicable only to wetted parts.
(20)
Not available with parabolic antenna.
(21)
Transmitters with aluminum housing are not approved for open deck installations; for use only in engine room, pump
room, etc.
(22)
Rosemount extended warranties have a limited warranty of three or five years from date of shipment.
Requires ½-14 NPT conduit/cable threads (code 1). Available with Intrinsically Safe approvals only.
(23)
A.5

Availability of process connections

Table A-13: Cone Antenna - 316/316L SST/EN 1.4404 (Type vs. Size and Rating)
Process
connection
(1)
Thread
size
1½-in.
G, N
2-in./
G, N
DN50/50A
3-in./
G, N
DN80/80A
4-in./
G, N
DN100/100A
6-in./
N/A
DN150/150A
8-in./
N/A
DN200/200A
(1)
BSPP (G) thread (process connection type code G); N = NPT thread (process connection type code N)
Rosemount 5408 and 5408:SIS Level Transmitters
and
Table
A-14).
Process connection rating
(2)
ASME B16.5 flanges
Class
Class
Class
(3)
(3)
(3)
150
300
600
N/A
N/A
N/A
R
R
R, T
R
R
R, T
R
R
R, T
R
R
N/A
R
R
N/A
Specifications and reference data
Figure A-4
for details.
EN1092-1 flanges
(4)
(4)
PN16
PN40
PN63
N/A
N/A
N/A
F
F, R
F, R
F, R
F, R
F, R
F, R
F, R
F
F, R
F, R
F
F, R
F, R
N/A
February 2020
(2)
JIS B2220
flanges
(5)
(5)
(3)
PN100
10K
20K
N/A
N/A
F
R
F, R
R
F
R
N/A
R
N/A
R
(2)
(5)
N/A
R
R
R
R
R
191

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rosemount 5408:sis

Table of Contents