Table A-11: Rosemount 5408 Level Transmitter Ordering Information
Conduit electrical connector (shipped uninstalled)
EC
M 12, 4-pin, Male connector (eurofast
MC
A size Mini, 4-pin, Male connector (minifast
Specials (see
Engineered
PXXXX
Custom Engineered Solutions beyond standard model codes. Consult factory for details.
Typical model number: 5408 A 1 S H A 1 E5 1 R 3 AB CAB 3 M5 DA1
(1)
G½ thread form is not available with hazardous locations approvals.
(2)
Not available with performance class code A (ultra accuracy)
(3)
Type A flat face for EN 1092-1 flanges.
(4)
Type B1 raised face for EN 1092-1 flanges.
(5)
For applications where saturated steam may occur, consult factory.
(6)
Pressure limit is derated for process temperatures above 100 °F (38 °C), see
(7)
Refer to
Figure A-6
for pressure/temperature ratings of Tri-Clamp connection.
(8)
1½-in. (DN40) cone antenna is available for 1½-in. NPT threaded connection and materials of construction code 1
(316/316L/EN 1.4404).
(9)
Option code PC1 is for cone antennas only, and requires matching flange and antenna sizes. Note that all parabolic
antennas come with an integrated air purge connection.
(10)
A minimum gasket thickness of 0.125 in. (3.2 mm) is required for flanges with protective plate design.
(11)
Only available with parabolic antenna, 3-in. (DN80) process seal antenna, and 4-in. (DN100) cone antenna.
(12)
The standard alarm setting is high.
(13)
Only applies to flanged process connections with welded construction or protective plate design; only applicable to
cone antennas (see
Table A-13
(14)
Flanged process connections with protective plate design are only available with ASME IX (option code AW).
(15)
Not available with EN1092-1 or JIS B2220 flanges, neither for ASME B16.5 flanges in materials of construction code M.
(16)
Hydrostatic testing is only available for cone antennas and process seal antennas with flanged process connections.
(17)
Certificate includes all pressure retaining and wetted parts.
(18)
Only available for process seal antennas with Tri-Clamp connection.
(19)
Applicable only to wetted parts.
(20)
Not available with parabolic antenna.
(21)
Transmitters with aluminum housing are not approved for open deck installations; for use only in engine room, pump
room, etc.
(22)
Rosemount extended warranties have a limited warranty of three or five years from date of shipment.
Requires ½-14 NPT conduit/cable threads (code 1). Available with Intrinsically Safe approvals only.
(23)
A.4.2
Rosemount 5408:SIS Level Transmitter
Table A-12: Rosemount 5408:SIS Level Transmitter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred
offerings are subject to additional delivery lead time.
Model
Product description
5408
Radar Level Transmitter
(1)
Profile
F
Functional Safety / SIS Applications
Measurement type
1
Liquid Level Measurement
Rosemount 5408 and 5408:SIS Level Transmitters
®
)
solutions)
and
Table
A-14).
(23)
®
)
Figure A-4