OPERATING INSTRUCTIONS
Failure to follow these instructions may reduce respirator performance, expose you to contaminants above the OEL, and may result in
sickness or death.
• If using D7N11 or D7P71 filters:
- ensure one is installed onto each side of the cartridge (two total per cartridge),
- ensure filters, filter retainer, and cartridge are aligned in the same orientation, and
- ensure filter retainer is properly connected on both sides of cartridge.
• When installing filters/cartridges onto facepiece ensure they audibly lock into place.
ASSEMBLY & REMOVAL
Cartridge/Filter Assembly & Removal
1. Align the port end of the cartridges or filters with the ports on the facepiece (Fig. 1).
2. Push the cartridge/filter into the connector until the blue cartridge/filter release button raises back with an audible sound (Fig. 2).
3. If the cartridge/filter does not lock into place when inserted, it may be due to the angle of insertion. Lift up slightly on the cartridge/filter until the
cartridge/filter locks into place (Fig. 3).
4. Ensure you connect a cartridge or filter to each side of the facepiece.
5. To remove the cartridge/filter depress the blue cartridge/filter release button and simultaneously pull outward on the cartridge/filter (Fig. 4).
Fig. 1
D7N11 & D7P71 Filter Assembly & Removal
1. Orient one filter in the larger half of the filter retainer so the shape of the filter aligns with the shape of the filter retainer. Ensure the printed side of
the filter is facing down (Fig. 5).
NOTE: The larger half of the filter retainer does NOT have the cutout end, while the smaller half has a cutout end so it fits around the cartridge
connection.
2. Align the larger half of the retainer with the back (flat side) of the cartridge. Using both hands, press the retainer onto the cartridge, ensuring you
press on all four corners of the cartridge/filter retainer (Fig. 6). The filter retainer has touchpoint indicators on each corner. You should hear the
retainer snap into place.
3. Orient a filter in the other half of the filter retainer so the shape of the filter aligns with the shape of the filter retainer and the printed side of the
filter faces down (Fig. 7). Wrap the opposite end of the retainer around the cartridge and assemble by pressing down on all four corners of the
cartridge/filter retainer (Fig. 8).
4. Ensure all sides of the filter retainer are fully engaged with the cartridge.
NOTE: The print on the filters should be visible when correctly attached to the cartridge. If filter print is not visible, remove the retainer and flip the
filters so the printed side of filters is facing outward.
5. To remove the retainer, pull upward on the retainer tabs until the retainer releases from the cartridge.
NOTE: Assemble cartridges and D7N11 or D7P71 filters to the facepiece according to the Cartridge/Filter Assembly & Removal procedure in these
User Instructions.
Fig. 5

FITTING INSTRUCTIONS

Failure to follow these instructions may reduce respirator performance, expose you to contaminants above the OEL, and may result in
sickness or death.
To help maintain a good seal between the face and the faceseal, the respirator faceseal must be clear of obstructions at all times. Do not use with
beards, facial hair or anything that prevents direct contact between the face and the respirator faceseal.