List Of Products; Replacement Parts - 3M Secure Click HF-800 Series User Instructions

Half facepiece reusable respirators
Table of Contents

Advertisement

Available languages

Available languages

Failure to follow these instructions may reduce respirator performance, expose you to contaminants above the OEL, and may result in
sickness or death.
• Ensure the speaking diaphragm is in place and installed correctly prior to use.
• Inspect all respirator components before each use to ensure proper operating condition.

List of Products

Number
Description
HF-801
Secure Click™ Half Facepiece Respirator, Small
HF-802
Secure Click™ Half Facepiece Respirator, Medium
HF-803
Secure Click™ Half Facepiece Respirator, Large
HF-801SD
Secure Click™ Half Facepiece Respirator, Speaking Diaphragm, Small
HF-802SD
Secure Click™ Half Facepiece Respirator, Speaking Diaphragm, Medium
HF-803SD
Secure Click™ Half Facepiece Respirator, Speaking Diaphragm, Large

Replacement Parts

HF-801SD, HF-802SD & HF-803SD (Fig. 17)
HF-801, HF-802 & HF-803 (Fig. 18)
Number
Letter
Description
HF-800-04
A
Head Harness Assembly, SD Version, 5/cs
HF-800-05
B
Speaking Diaphragm, 5/cs
HF-800-02
C
Inhale/Exhale valve, 10/cs
HF-800-01
D
Head Harness Assembly, Non-SD Version, 5/cs
Number
Description
504
Respirator Cleaning Wipe, 100/cs
HF-800-03
Quantitative Fit Test Adapter Kit, 1/cs
Replacement of Head Harness
1. Remove head harness assembly by pulling down and outward on the bottom of the head harness assembly until it clears the bottom of the
facepiece (Fig. 19).
2. Lift the head harness assembly away from the facepiece.
3. Replace head harness assembly by positioning the ledge on the head harness assembly into the notch at the top of the facepiece (Fig. 20, #1).
4. Press the bottom of the head harness assembly into the facepiece (Fig. 20, #2). When properly engaged, an audible snap should be heard.
Inhalation Valve Replacement
The inhalation valve is located on the inside of the facepiece above the exhalation valve.
NOTE: The inhalation and exhalation valves are the same design, replacement part HF-800-02.
1. Remove inhalation valve by grasping valve and pulling valve off the center post (Fig. 21).
2. Replace valve by aligning the valve stem with the hole in the center of the valve seat (Fig. 22).
3. Press the valve post through the hole in the valve seat (Fig. 23). Be certain valve is fully engaged through valve post and lays flat against the valve
seat.
W WARNING
C
B
A
C
Fig. 17
Fig. 19
C
D
C
Fig. 18
1
2
Fig. 20
Printed Colors – Front:
Requester: Susan Anderson
Creator:
deZinnia_24567
File Name: 24567-2 Facepiece Facia with t test adapter_PSD.ai
Scale:
Structure #: Illustration
1 Inch
Date:
10/09/18
This artwork has been created as requested by 3M. 3M is responsible for the artwork
AS APPROVED and assumes full responsibility for its correctness.
7