Object Data Points and Diagnostic Data Points
Table 4.
Analog Input (continued)
Object Identifier
Analog Input, 28
Duct Static Air Pressure Active
Analog Input, 29
Duct Static Air Pressure Local
Analog Input, 30
Return Fan Air Pressure
Analog Input, 31
Space Static Air Pressure Active
Analog Input, 32
Space CO
Analog Input, 33
Discharge Air Temperature Dewpoint
Analog Input, 34
Outdoor Air Flow Active
Analog Input, 35
Condenser Water Entering Temperature
Analog Input, 36
Evaporator Entering Temperature Circuit 1
Analog Input, 37
Evaporator Entering Temperature Circuit 2
Analog Input, 38
Evaporator Leaving Temperature Circuit 1
Analog Input, 39
Evaporator Leaving Temperature Circuit 2
Analog Input, 40
Evaporator Leaving Temperature Circuit 3
Analog Input, 41
Evaporator Leaving Temperature Circuit 4
Analog Input, 42
Condensing Saturated Temperature Circuit 1
Analog Input, 43
Condensing Saturated Temperature Circuit 2
Analog Input, 44
Condensing Saturated Temperature Circuit 3
Analog Input, 45
Condensing Saturated Temperature Circuit 4
Analog Input, 46
Condenser Water Leaving Temperature Active
Analog Input, 47
Condenser Water Leaving Temperature Local
Analog Input, 48
Duct Static Air Pressure Setpoint Active
Analog Input, 50
Space Air Temperature Setpoint Active
Analog Input, 52
Discharge Air Temperature Setpoint Active
Morning Warmup Air Temperature Setpoint
Analog Input, 54
Active
Daytime Warmup Air Temperature Initiate
Analog Input, 55
Setpoint Active
Analog Input, 56
Economizer Minimum Position Setpoint Active
Analog Input, 57
Outdoor Air Minimum Flow Setpoint Active
Analog Input, 58
Dehumidification High Limit Setpoint
Discharge Air Dewpoint Temperature
Analog Input, 60
Setpoint
Analog Input, 61
Discharge Air Reheat Setpoint Active
Analog Input, 62
Space Humidification Setpoint Active
26
Object Name
Concentration Active
2
Description
Duct static air pressure value currently being used for
unit control.
Duct static air pressure value measured by a unit-
mounted sensor.
Return fan air pressure value measured by a unit-
mounted sensor.
Space static air pressure value being used for unit
control.
Space CO
concentration being used for unit control.
2
Discharge air temperature dewpoint being used by the
unit.
Outdoor airflow utilitzed by the unit.
The temperature of the water entering the condenser.
Indicates the entering evaporator temperature for
circuit 1.
Indicates the entering evaporator temperature for
circuit 2.
Indicates the leaving evaporator temperature for
circuit 1
Indicates the leaving evaporator temperature for
circuit 2.
Indicates the leaving evaporator temperature for
circuit 3.
Indicates the leaving evaporator temperature for
circuit 4.
Indicates the saturated condenser temperature for
circuit 1.
Indicates the saturated condenser temperature for
circuit 2.
Indicates the saturated condenser temperature for
circuit 3.
Indicates the saturated condenser temperature for
circuit 4.
Condenser water leaving temperature value used for
unit control.
Condenser water leaving temperature from a unit-
mounted sensor.
Duct static pressure setpoint value being used for unit
control.
Space temperature setpoint value being used for unit
control.
Discharge air temperature setpoint value being used
for unit control.
The air temperature setpoint used during morning
warmup mode.
The air temperature setpoint used to start daytime
warmup mode.
The minimum position value the economizer damper
will utilize.
The minimum outdoor airflow setpoint being utilized by
the unit.
Humidity setpoint value that starts dehumidification
control.
Humidity setpoint value used during dehumidification
control.
Indicates the active supply air reheat temperature
setpoint.
Indicates the setpoint used during space humidification
control.
Units (Listed Are Defaults)
Inches-of-water (58)
Inches-of-water (58)
Inches-of-water (58)
Inches-of-water (58)
Parts-per-million (96)
Degrees-Fahrenheit (64)
Cubic-feet-per-minute (84)
Degrees-Fahrenheit (64)
Degrees-Fahrenheit (64)
Degrees-Fahrenheit (64)
Degrees-Fahrenheit (64)
Degrees-Fahrenheit (64)
Degrees-Fahrenheit (64)
Degrees-Fahrenheit (64)
Degrees-Fahrenheit (64)
Degrees-Fahrenheit (64)
Degrees-Fahrenheit (64)
Degrees-Fahrenheit (64)
Degrees-Fahrenheit (64)
Degrees-Fahrenheit (64)
Inches-of-water (58)
Degrees-Fahrenheit (64)
Degrees-Fahrenheit (64)
Degrees-Fahrenheit (64)
Degrees-Fahrenheit (64)
Percent (98)
Cubic-feet-per-minute (84)
Percent (98)
Degrees-Fahrenheit (64)
Degrees-Fahrenheit (64)
Percent (98)
ACC-SVP01B-EN • BCI-I Integration Guide