3 December 2004
SP 1-008 to 014: Density setup examples
These values control the image density for the 7 settings on the operation panel.
Here are three examples
Case 1: There is a relatively small difference between the minimum and maximum
settings
Case 2: The higher values in this example make the image lighter.
Case 3: The lower values in this example make the image darker.
Density
Case
setup 1
1
85
2
70
3
10
NOTE: These are reference values. Adjust them to get the best results.
Density
Density
setup 2
setup 3
100
115
100
130
40
70
5-3
SERVICE PROGRAM MODE
Density
Density
setup 4
setup 5
130
145
160
190
100
130
Density
Density
setup 6
setup 7
160
175
220
250
160
190