Pin No.

Function

6.2.2 Connecting PRI
TEPRI/TEPRIa cards can be connected to a PRI C.O. line through a RJ-45 port. As
shown below, connect a PRI C.O. line to the T1/E1/PRI port of the OfficeServ 7100
system.
Using a standard, straight through eight conductor data cable or straight through eight
conductor line cord to connect the customer provided Channel Service Unit (CSU) to
the TEPRI/TEPRIa card as shown in
NOTES:
1. It may be necessary to cut off the CSU end of the cable and attach a different
connector to match that of the CSU. If possible, this connection should be soldered
because good connections are critical.
2. It is recommended that the CSU be connected to the network interface with a cable
supplied by the CSU manufacturer. If this is not possible or practical, a custom
cable has to be made up. This cable should be made from 22 gauge two pair cable
with each pair individually shielded. It is recommended that the connections on this
cable be soldered wherever possible to ensure good connections. The shielding of
the cable should be connected to ground at the CSU end only to prevent a ground
loop.
Pin No.
1
T1
Rx+
Function
PRI
Function
1
2
3
-
-
-
Figure 6.1 8TRK Card Ports(P1~P8) or 4TRM port(P1~P4)
Figure 6.2.
2
3
Rx-
-
-
-
-
Figure 6.2 RJ-45 Port of TEPRI/TEPRIa Card
6.2
Home Page
4
5
6
C.O.
C.O.
-
TIP
RING
T1/PRI Port
(RJ-45)
4
5
6
Tx+
Tx-
-
Tx+
Tx-
-
Table of Contents
INSTALLATION
PART 6 APRIL 2007
7
8
-
-
7
8
-
-
Rx+
Rx-