2.7.3 TAWS Activation (if installed)

Perform this procedure only if the aircraft is to be equipped with the Garmin TAWS option.
1. Remove power from the PFD by opening the PFD circuit breaker.
2. A special TAWS Unlock card is required to enable TAWS. Refer to the appropriate General
Arrangement drawing for the correct part number. Insert this card in the upper slot of the PFD.
3. While holding the ENT key on the PFD and MFD, restore power to the displays.
4. When the words
release the ENT keys.
5. On the PFD, go to the System Upload page using the FMS knob.
6. Activate the cursor. Use the small FMS knob to select CONFIGURATION FILES in the
AIRFRAME field and press the ENT key.
7. Highlight the FILE field. Use the small FMS knob to select the 'Enable TAWS' option and press
the ENT key. Once the option is selected, the configuration files in the PRODUCT field will be
displayed. All files should be checked. If not, press the CHK ALL softkey.
8. Press the LOAD softkey.
9. Monitor the status of the upload. When the upload is finished, press the ENT key to acknowledge
the upload complete confirmation.
10. View the SUMMARY field and ensure that the item is 'COMPLETE'.
11. De-activate the cursor.
12. Power down the system and remove the TAWS Enable card from the PFD.

2.7.4 ChartView (if installed)

ChartView databases are subscription-based and are to be procured by the aircraft owner directly
from Jeppesen. This procedure is only required if the ChartView option is purchased by the
customer.
1. Remove power from the PFD by opening the PFD circuit breaker.
2. A special ChartView Unlock card is required to activate this feature. Refer to the appropriate
General Arrangement drawing for the correct part number. Insert this card in the upper slot of the
PFD.
3. While holding the ENT key on the PFD and MFD, restore power to both displays by closing the
PFD and MFD circuit breakers.
4. When the words
release the ENT key.
5. On the PFD, go to the System Upload page using the FMS knob.
6. Activate the cursor. Use the small FMS knob to select CONFIGURATION FILES in the
AIRFRAME field and press the ENT key.