7.2 Hardware/software requirements

7.2
Hardware/software requirements
Hardware requirements
The following requirements must be met for commissioning the SIMATIC Drive Controller:
● Your plant has been installed and wired.
● Your PG/PC has been connected to the SIMATIC Drive Controller over the PROFINET or
PROFIBUS interface.
Software requirements
Table 7- 1
Configuration in the TIA Portal
Integrated SIMATIC S7-1500 CPU
SINAMICS Integrated
Additional information
You can find an overview of the most important documents and links for the TIA Portal on
the Internet (https://support.industry.siemens.com/cs/en/en/view/65601780).
You can find manuals, application examples and FAQs on Motion Control
(https://support.industry.siemens.com/cs/ww/en/view/109751049) on the following topic
page.
Note
Configuration without STEP 7/SINAMICS Startdrive
If you want to open projects that already contain a SIMATIC Drive Controller and a
SINAMICS drive, you need STEP 7 and SINAMICS Startdrive, even if the controller or the
drive are subsequently deleted.
Note
Connecting SINAMICS Integrated online
To connect SINAMICS Integrated online:
• You need STEP 7 Professional and SINAMICS Startdrive (V16.0 or higher).
• The hardware configuration must have been loaded to the SIMATIC Drive Controller.
• A subnet must be configured at the interface to which you are connecting your PC/PC.
You can only configure the drive offline with SINAMICS Startdrive without STEP 7
Professional.
92
Required configuration software
Requirement
SIMATIC STEP 7 Professional, V16 or higher
SINAMICS Startdrive Basic or Startdrive Advanced,
V16 or higher
System Manual, 11/2019, A5E46600094-AA
SIMATIC Drive Controller