Digital output module dq 8x230vac/2a st triac (32 pages)
Summary of Contents for Siemens SIMATIC S7-1500
Page 1
Edition 5/2022 MANUAL SIMATIC S7-1500 / ET 200MP Communucation module IO-Link Master CM 8xIO-Link 6ES7547-1JF00-0AB0 support.industry.siemens.com...
Page 2
S7-1500/ET 200MP Documentation Guide Product overview SIMATIC Connecting S7-1500/ET 200MP Communication module IO-Link Parameters / address space Master CM 8xIO-Link (6ES7547-1JF00-0AB0) Diagnostic alarms Equipment Manual Technical specifications Dimensional drawing Parameter data record 08/2022 A5E45488510-AB...
Page 3
Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical doc umentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and mainten...
Page 4
Siemens' products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customers' exposure to cyber threats.
Page 5
Preface To stay informed about product updates, subscribe to the Siemens Industrial Security RSS Feed visit (https://www.siemens.com/industrialsecurity). Open Source Software Open-source software is used in the firmware of the I/O modules. Open Source Software is provided free of charge. We are liable for the product described, including the open-source software contained in it, pursuant to the conditions applicable to the product.
S7-1500/ET 200MP Documentation Guide S7-1500 / ET 200MP Documentation Guide The documentation for the SIMATIC S7-1500 automation system and the ET 200MP distributed I/O system is arranged into three areas. This arrangement enables you to access the specific content you require. Changes and supplements to the manuals are documented in a Product Information.
ET 200MP distributed I/O system gathered together in one file. You can find the Manual Collection on the Internet. (https://support.industry.siemens.com/cs/ww/en/view/86140384) SIMATIC S7-1500 comparison list for programming languages The comparison list contains an overview of which instructions and functions you can use for which controller families.
Page 9
SIOS on your mobile device: Quick introduction to the technical documentation of automation products per video ( https://support.industry.siemens.com/cs/us/en/view/109780491 YouTube video: Siemens Automation Products - Technical Documentation at a Glance ( https://youtu.be/TwLSxxRQQsA mySupport With "mySupport" you can get the most out of your Industry Online Support.
You can find the SIMATIC Automation Tool on the Internet. (https://support.industry.siemens.com/cs/ww/en/view/98161300) PRONETA SIEMENS PRONETA (PROFINET network analysis) is a commissioning and diagnostic tool for PROFINET networks. PRONETA Basic has two core functions: • The "Network analysis" offers a quick overview of the PROFINET topology. It is possible to make simple parameter changes (for example, to the names and IP addresses of the devices).
Page 11
S7-1500/ET 200MP Documentation Guide 1.3 Tool support SIEMENS PRONETA Professional is a licensed product that offers you additional functions. It offers you simple asset management in PROFINET networks and supports operators of automation systems in automatic data collection/acquisition of the components used through various functions: •...
Product overview Properties Article number 6ES7547-1JF00-0AB0 View of the module Figure 2-1 View of the IO-Link Master CM 8xIO-Link communication module Properties The module has the following technical properties: • IO-Link master according to IO-Link specification V1.1 • Communication module with 8 ports (channels) •...
• Front connectors, including potential jumpers and cable ties Additional information You can find more information on accessories in the S7-1500/ET 200MP Distributed I/O Sys tem (https://support.industry.siemens.com/cs/ww/en/view/59191792) system manual in the Accessories/Spare parts section. Functions IO-Link is a point-to-point connection between a master and a device. Both conventional and...
The switching state and data channels are designed with trusted 24 V DC technology. Reference Additional information can be found in the IO-Link System (https://support.automation.siemens.com/WW/view/en/65949252) function manual. Replacing the IO-Link Master CM 8xIO-Link communication module Master Backup You can back up the parameters of your module with the function block "LIOLink_Master".
Page 15
Product overview 2.4 Reset communication module to factory settings After a "Reset to factory settings", the parameters of the IO-Link Master CM 8xIO-Link communication module are assigned as follows: • The ports are in DI mode • The ports are mapped to the relative addresses 0.0 ... 0.7 •...
Connecting Wiring and block diagram This section includes the block diagram of the communication module IO‑Link Master CM 8xIO‑Link with the terminal assignments for 3-wire and 5-wire connection of IO-Link devices or 2-wire and 3-wire connection in DI operating mode. You can use and combine the different wiring options for all channels. Ensure that all devices are connected to the SELV/PELV power supply (or equivalent).
Page 17
Connecting 3.1 Wiring and block diagram Wiring: 3-wire and 5-wire connection of IO-Link devices The example in the following figure shows the terminal assignment of the communication module IO‑Link Master CM 8xIO‑Link (3- and 5-conductor connection of IO-Link devices). ① Reverse polarity protection Supply voltage (positive) ②...
Page 18
Connecting 3.1 Wiring and block diagram Wiring: 2-wire and 3-wire connection in DI operating mode The example in the following figure shows the terminal assignment of the IO‑Link Master CM 8xIO‑Link communication module in DI operating mode. ① Reverse polarity protection Supply voltage (positive) ②...
Parameters / address space Parameters Parameters (GSD file) The following table shows the general parameters for the IO-Link Master CM 8xIO-Link communication module. The default settings of the parameters are marked in bold in the "Value ranges" column. Table 4-1 General parameters (GSD file) Parameters Value range Effective range...
For the remaining ports, you can assign a total of 60 bytes of input data. Reference You can find additional information on the Vendor ID and Device ID on the Internet (https://support.industry.siemens.com/cs/ww/en/view/109748852). Declaration of parameters Diagnostics: No supply voltage L+ Enabling the diagnostic alarm for missing or insufficient supply voltage L+.
Page 21
• Type-compatible (V1.1) without Backup&Restore • Type-compatible (V1.1) with Backup&Restore • Type-compatible (V1.1) with Restore You can find instructions for determining the Vendor ID and Device ID on the Internet (https://support.industry.siemens.com/cs/ww/en/view/109748852). The port operates as standard digital input. Deactivated The port is deactivated.
Parameters / address space 4.3 Address space Address space Configuration options of the communication module IO-Link Master CM 8xIO-Link The size of the input and output addresses of the IO-Link Master CM 8xIO-Link communication module with firmware version V1.0 are 32 bytes per port in each case. The following table provides an overview of the configuration options of the supported address areas for I/O data: Module configuration...
Page 23
In connection with an IM 155-5 DP ST, you configure the IO-Link master exclusively using a GSD file. Install the corresponding GSD file. You can find this for download on the Internet (https://support.industry.siemens.com/cs/ww/en/view/80206700). Port configuration CPU With an IO-Link Master CM 8xIO-Link, you can commission the IO-Link ports of the IO-Link Master or the connected IO-Link devices in two different ways: •...
Page 24
Parameters / address space 4.3 Address space You deselected the "Port configuration without S7-PCT" check box in the configuration of the IO-Link master in STEP 7. Procedure You configure the IO-Link Master ports with the Port Configuration Tool S7-PCT, V3.5 SP1 or higher.
Page 25
Figure 4-3 Address space of the inputs of the IO-Link Master CM 8xIO-Link in standard DI mode Reference You can find additional information in the IO-Link System (https://support.automation.siemens.com/WW/view/en/65949252) function manual. Communication module IO-Link Master CM 8xIO-Link (6ES7547-1JF00-0AB0) Equipment Manual, 08/2022, A5E45488510-AB...
Diagnostic alarms Status and error displays LED display Port status/channel error Channel status in standard DI mode Supply voltage L+ Channel number Figure 5-1 LED display Meaning of the LED displays The following tables show the meaning of the status and error displays. Remedial measures for diagnostic alarms can be found in the Diagnostic alarms (Page 28) chapter.
Page 27
Diagnostic alarms 5.1 Status and error displays RUN and ERROR LED Table 5-1 Status and error displays RUN and ERROR Meaning Solution ERROR Voltage missing or too low at backplane • Switch on the CPU and/or the system bus. power supply modules. •...
Diagnostic alarms 5.2 Diagnostic alarms Qn LEDs Valid for the IO-Link port that is in standard DI mode. Table 5-4 Status displays of LEDs Q1 to Q8 Q1 to Q8 Meaning Process signal = 0 in standard DI mode, deactivated or in IO-Link mode Process signal = 1 in standard DI mode On (green)
Page 29
Diagnostic alarms 5.2 Diagnostic alarms Diagnostic alarm Error Meaning (IO-Link error code) IO-Link IO-Link code Master device Defective fuse • Fuse on device is defective (5101 Safety shutdown • Serious error (master has to be replaced) (1880 External fault 1 A •...
Technical specifications of the IO-Link Master CM 8xIO-Link communication module The following table shows the technical specifications as of the issue date. You can find a data sheet including daily updated technical specifications on the Internet (https://support.industry.siemens.com/cs/de/en/pv/6ES7547-1JF00-0AB0/td?dl=en). Article number 6ES7547-1JF00-0AB0 General information ...
Page 31
Technical specifications Article number 6ES7547-1JF00-0AB0 IO-Link protocol 1.1 Cycle time, min. 2 ms Size of process data, input per port 33 byte; max. Size of process data, input per module 240 byte; max. Size of process data, output per port 32 byte; max. Size of process data, output per module 240 byte;...
Page 32
Technical specifications Article number 6ES7547-1JF00-0AB0 Isolation Isolation tested with 707 V DC (type test) Ambient conditions Ambient temperature during operation • horizontal installation, min. -30 °C horizontal installation, max. 60 °C; Observe derating • • vertical installation, min. -30 °C vertical installation, max.
Dimensional drawing Dimensional drawing The dimensional drawing of the module on the mounting rail, as well as a dimensional drawing with open front panel, are provided in the appendix. Always observe the specified dimensions for installation in cabinets, control rooms, etc. Figure 7-1 Dimensional drawing of the IO-Link Master CM 8xIO-Link module Communication module IO-Link Master CM 8xIO-Link (6ES7547-1JF00-0AB0) Equipment Manual, 08/2022, A5E45488510-AB...
Page 34
Dimensional drawing 7.1 Dimensional drawing Figure 7-2 Dimensional drawing of the IO-Link Master CM 8xIO-Link module, side view with open front cover Communication module IO-Link Master CM 8xIO-Link (6ES7547-1JF00-0AB0) Equipment Manual, 08/2022, A5E45488510-AB...
Parameter data record Parameter assignment and structure of parameter data set The data record of the module has an identical structure, regardless of whether you configure the module with PROFIBUS DP or PROFINET IO. With data record 128, you can reconfigure the module in your user program regardless of your programming.
Page 36
Parameter data record A.1 Parameter assignment and structure of parameter data set Structure of data record 128 Figure A-1 Structure of data record 128 Header information The figure below shows the structure of the header information. Figure A-2 Header information Communication module IO-Link Master CM 8xIO-Link (6ES7547-1JF00-0AB0) Equipment Manual, 08/2022, A5E45488510-AB...
Page 37
Parameter data record A.1 Parameter assignment and structure of parameter data set IO-Link start parameters The following figure shows the structure of the IO-Link start parameter. Activate a parameter by setting the corresponding bit to "1". Figure A-3 IO-Link start parameters Port parameter The following figure shows an extract from the structure of the port parameter.
Page 38
Parameter data record A.1 Parameter assignment and structure of parameter data set If you have selected IO-Link Manual operating mode, you must enter the Vendor ID (byte x+5 and x+6) and Device ID (byte x+7 to x+10) yourself. You can find the Vendor ID and Device ID in the IODD of the IO-Link device being used. Communication module IO-Link Master CM 8xIO-Link (6ES7547-1JF00-0AB0) Equipment Manual, 08/2022, A5E45488510-AB...
Page 39
Parameter data record A.1 Parameter assignment and structure of parameter data set Figure A-4 Port parameter Communication module IO-Link Master CM 8xIO-Link (6ES7547-1JF00-0AB0) Equipment Manual, 08/2022, A5E45488510-AB...