Output
Frequency
Level
10 kHz
120 kHz
500 kHz
2 MHz
30 mV
5 MHz
10 MHz
20 MHz
30 MHz
10 kHz
120 kHz
500 kHz
2 MHz
10 mV
5 MHz
10 MHz
20 MHz
30 MHz
10 kHz
120 kHz
500 kHz
2 MHz
3 mV
5 MHz
10 MHZ
20 MHz
30 MHz
10 kHz
120 kHz
500 kHz
2 MHz
1 mV
5 MHZ
10 MHz
20 MHz
30 MHz
Table 23. Wideband Flatness Test Record (cont.)
Spec
Measured
Flatness
± ppm
Error
(90-day)
1000
1000
1100
1100
2100
2100
4100
10100
1000
1000
1300
1300
2300
2300
4300
10300
1000
1000
2000
2000
4000
4000
6000
16000
1000
1000
5000
5000
7000
7000
9000
30000
5790A
TUR
GB Factor
1-Year
Spec
500
2.00
0.932
500
2.00
0.932
500
2.20
0.945
500
2.20
0.945
1000
2.10
0.939
1000
2.10
0.939
1500
2.73
0.972
3500
2.89
0.977
500
2.00
0.932
500
2.00
0.932
700
1.86
0.920
700
1.86
0.920
1000
2.30
0.950
1000
2.30
0.950
1700
2.53
0.962
3700
2.78
0.972
500
2.00
0.932
500
2.00
0.932
1033
1.94
0.928
1033
1.94
0.928
1333
3.00
0.980
1333
3.00
0.980
2033
2.95
0.978
4033
3.97
0.999
500
2.00
0.932
500
2.00
0.932
1700
2.94
0.978
1700
2.94
0.978
2700
2.59
0.965
2700
2.59
0.965
4000
2.25
0.948
9000
3.33
0.988
Multifunction Calibrator
Wideband Output Flatness Test
Test Limit
± ppm
932
932
1040
1040
1972
1972
3985
9868
932
932
1196
1196
2185
2185
4137
10012
932
932
1856
1856
3920
3920
5868
15984
932
932
4890
4890
6755
6755
8532
29640