11
STEP 1
STEP 2
STEP 3
STEP 4
STEP 1
STEP 2
STEP 3
STEP 4
241
CPE VLAN to VLAN
To support the CPE MUX with subscribers VLANs, subscribers may require multiple video
providers, and each provider is assigned a different external VLAN.
CPE (internal) Multicast VLANs must be mapped to the Multicast provider (external)
VLANs.
After a CPE VLAN is mapped to a Multicast VLAN, it can participate in IGMP snooping.
To map CPE VLANs:
Click VLAN Management > Customer Port Multicast TV VLAN > CPE VLAN to
VLAN.
Click Add.
Enter the following fields:
CPE VLAN—Enter the VLAN defined on the CPE box.
Multicast TV VLAN—Select the Multicast TV VLAN which is mapped to the CPE
VLAN.
Click Apply. CPE VLAN Mapping is modified, and written to the Running Configuration file.
Port Multicast VLAN Membership
The ports associated with the Multicast VLANs must be configured as customer ports (see
Interface
Settings).
To map ports to Multicast TV VLANs:
Click VLAN Management > Customer Port Multicast TV VLAN > Port Multicast VLAN
Membership.
Select a VLAN from Multicast TV VLAN.
Select an interface from Interface Type.
The Candidate Customer Ports list contains all access ports configured on the device. Move
the required ports to the Member Customer Ports field.
Cisco Sx350, SG350X, SG350XG, Sx550X & SG550XG Series Managed Switches, Firmware Release 2.2.5.x