LIGHTING THE PILOT

1. Turn thermostat OFF. Thermostat is located behind the door
(Fig. 2).
2. Turn gas control valve knob to OFF/PILOT (Fig. 3). Wait 5
minutes for unburned gas to vent.
3. Push gas control knob in (Fig. 3).
4. While still holding knob in, light the pilot with a lit taper. Continue
to depress knob for 30 seconds, then release the knob. Pilot
should remain lit when knob is released.
If pilot does not remain lit, repeat Steps 2, 3, and 4.
5. Turn gas control knob to ON (Fig. 4).
6. If gas supply is interrupted, repeat Steps 1-5.
Fig. 3

TURNING THE FRYER ON

To turn the fryer on, set the thermostat knob to the desired temperature. After the set temperature has
been reached, the gas control shuts off gas flow to the burners. The pilot remains lit. The burners will
cycle on and off, maintaining the set temperature.

TURNING THE FRYER OFF

1. Turn the thermostat OFF.
2. Turn the gas control valve knob to PILOT. In this position the pilot will remain lit.
3. To shut off all gas to the system, including the pilot, turn the gas control valve knob to OFF.

EXTENDED SHUTDOWN

1. Turn the manual gas shutoff valve OFF.
2. Turn the thermostat knob OFF.
3. Turn the gas control valve knob to OFF.
Fig. 4