Miele PDR 908 EL Operating And Installation Instructions page 71

Vented
Hide thumbs Also See for PDR 908 EL:
Table of Contents

Advertisement

Examples
Connection to a ventilation stack
a Pipe with connector
(= individual parts in the Miele Wall
Pipe)
b Adapter for a flexible exhaust-air
hose
c Ventilation stack, moisture-proof
Risk of toxic fumes due to the
intake of poisonous exhaust gas.
The tumble dryer extracts air for
drying from the room where the
appliance is installed. If the
appliance is operated at the same
time as fireplaces or other technical
equipment in the area of influence in
the installation room, toxic exhaust
gases can be sucked back in.
Exhaust air must not be vented into a
chimney or vent flue which is
otherwise in use and must not be
channeled into ducting which
ventilates rooms with fireplaces.
Installing the ducting
Window connection
a Window connection (inserted in a
pane of Perspex)
b Adapter for a flexible exhaust-air
hose
Condensation may run into the
tumble dryer.
Do not lay the exhaust-air hose in
loops. Cut the exhaust-air hose to
the required length.
71