Installing the ducting
Sample calculation
A
Wall pipe, with inserted
grille
= 1 x 3.8 m relative pipe
length
B/D 2 bends, 90° plastic waste-
water pipe
= 2 x 0.8 m relative pipe
length
C
0.5 m plastic waste-water
pipe
= 0.5 x 1 m relative pipe
length
Total duct length
Because the total duct length is less
than 65' 7 3/8" (20 m) (according to
table II), a pipe diameter of 4" (100 mm)
will be sufficient.
Exhaust-air outlets on the back
of the tumble dryer
Sealing the exhaust-air outlets
The ducting is installed on the right or
left-hand side of the tumble dryer's
back panel. You must seal the unused
connection with a cap.
68
 Turn the cap to the left to remove it.
 Press the cap firmly into the open air
outlet.
Dimensions of the exhaust-air outlets
= 12' 5 5/8"
(3.8 m)
= 5' 3"
(1.6 m)
= 1' 7 11/16"
(0.5 m)
= 19 4 5/16"
(5.9 m)
All measurements in inch (mm)