Installation
Install the Gun and Mounting
Bracket
1. Loosen the mounting bracket's two set screws (103)
and slide the bracket (102) onto a 1/2 in. (13 mm)
mounting rod. See F
2. Position the gun and tighten the two set screws.
NOTE: For added positioning reliability, insert a 1/8 in.
(3 mm) locating pin (NN) into the slot in the bracket and
through a hole in the rod. See the detail in F
102
103
NN
03460
F
. 6. Mounting Bracket
IG
10
. 6.
IG
. 6.
IG
2.88 in.
(73.2 mm)
To nozzle tip
7.39 in.
(187.7 mm)
8.75 in.
(222.3 mm)
TI13428a
Connect the Air and Fluid Lines
F
. 2 shows a schematic of air and fluid line connec-
IG
tions, and F
. 7 shows the manifold connections. Con-
IG
nect the air and fluid lines as instructed.
To reduce the risk of electric shock or other serious
injury, the turbine air supply hose must be electrically
connected to a true earth ground. Use only Graco
Grounded Air Supply Hose.
1. Connect the Graco Grounded Air Supply Hose (B)
to the gun's turbine air inlet (TA) and connect the
hose ground wire (A) to a true earth ground (N). The
gun turbine air inlet fitting has left-hand threads to
prevent connecting another type of air hose to the
turbine air inlet. See Accessories on page 44 for
further information about the hose.
2. Check the electrical grounding of the gun as
instructed on page 13.
3. Before connecting the fluid line (P1), blow it out with
air and flush it with solvent. Use solvent which is
compatible with the fluid to be sprayed.
313227E