Graco X5 Operation Operation Manual

Graco X5 Operation Operation Manual

Airless sprayers
Hide thumbs Also See for X5 Operation:

Advertisement

Operation
X5
, X7
,
Airless Sprayers
US Patent 6,752,067
European Patent 1 208 287
Korean Patent 10-0668583
Taiwan Patent No. D124860 for "Pro X7 Airless Paint Sprayer (Design)"
Chinese Patent ZL200730154436.7 for Pro X7
- For portable spray applications of architectural paints and coatings -
(Specifications, page 2.)
IMPORTANT SAFETY INSTRUCTIONS.
Read all warnings and instructions in this
manual. Save these instructions. See page
2 for model and series information including
dispense rate, recommended hose length,
guns, and maximum working pressure.
M
AGNUM
Model: 262805
Graco Inc. P.O. Box 1441 Minneapolis, MN 55440-1441
Copyright 2007, Graco Inc. is registered to I.S. EN ISO 9001
ProX7
& ProX9
M
X5
AGNUM
Model: 262800
ti11304a
X7
ti11305a
X5 & X7 Models ONLY: Use water-based or
mineral spirit-type materials only. Do not use
materials having flash points lower than 70° F
(21° C). For more information about your
material, request MSDS from distributor or
retailer.
M
ProX7
AGNUM
Model: 261815
ti9369a
The manual provided with
this sprayer contains
English and Español.
Visit our website;
http://M
.Graco.com
AGNUM
312001G
M
ProX9
AGNUM
Model: 261820
ti9368a

Advertisement

Table of Contents
loading

Summary of Contents for Graco X5 Operation

  • Page 1 MSDS from distributor or AGNUM retailer. Model: 262800 ti11304a ProX9 ProX7 AGNUM AGNUM AGNUM Model: 262805 Model: 261815 Model: 261820 ti11305a ti9369a ti9368a Graco Inc. P.O. Box 1441 Minneapolis, MN 55440-1441 Copyright 2007, Graco Inc. is registered to I.S. EN ISO 9001...
  • Page 2: Specifications

    Specifications Specifications This equipment is not intended for use with flammable or combustible materials used in places such as cabinet shops or other “factory”, or fixed locations. If you intend to use this equipment in this type of appli- cation, you must comply with NFPA 33 and OSHA requirements for the use of flammable and combustible materials.
  • Page 3 Warnings Warnings The following warnings are for the setup, use, grounding, maintenance and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbol refers to procedure-spe- cific risks. Refer back to these warnings. Additional, product-specific warnings may be found throughout the body of this manual where applicable.
  • Page 4 • Check hoses and parts for signs of damage. Replace any damaged hoses or parts. • This system is capable of producing 3000 psi. Use Graco replacement parts or accessories that are rated a minimum of 3000 psi. • Always engage the trigger lock when not spraying. Verify the trigger lock is functioning prop- erly.
  • Page 5 Do not kink or over-bend the hose. • Do not expose the hose to temperatures or to pressures in excess of those specified by Graco. • Do not use the hose as a strength member to pull or lift the equipment.
  • Page 6: Installation

    Installation Installation Grounding and Electric Smaller gauge or longer extension cords may Requirements reduce sprayer performance. Fluid supply container: follow local code. Solvent pails used when flushing: follow local code. Use only conductive metal pails, placed on a grounded surface such as concrete. Do not place Sprayer must be grounded.
  • Page 7: Component Identification

    Component Identification Component Identification Airless spray gun Dispenses fluid. Power switch Turns sprayer ON and OFF. Increases (clockwise) and decreases (counter-clockwise) fluid pressure Pressure control knob in pump, hose, and spray gun. To select function, align symbol on pressure control knob with setting Setting Indicator indicator, page 9.
  • Page 8 Component Identification ti9724a ti9346a ti9670a ti9368a ti9669a V (SG20) V (SG10) ti9668a ti11455a ti9667a 312001G...
  • Page 9: Operation

    Operation Operation Trigger Lock 2. Turn Prime/Spray valve to Always engage the trigger lock when you stop PRIME to relieve pressure. spraying to prevent the gun from being triggered accidentally by hand or if dropped or bumped. ti9346a 3. Hold gun firmly to side of pail.
  • Page 10: Prime And Flush Storage Fluid

    Setup Setup Prime and Flush Storage Fluid 1. Unscrew tip and guard assembly from gun. To spray lacquers with the ProX7 or ProX9, you must purchase lacquer conversion kit 256212, and follow priming procedure for oil-based materials. The X5 and X7 units are not intended for lacquers.
  • Page 11 Setup 2. Separate prime tube (smaller) 10. Turn power switch OFF. from suction tube (larger). ti2810a 11. Transfer suction tube to ti2039a paint pail and submerge suction tube in paint. 3. Place prime tube in waste pail. ti9653a 12. Turn power switch ON. ti9652a ti5580a 4.
  • Page 12: Install Tip And Guard On Gun

    Setup Install Tip and Guard on Gun Spraying Techniques Preventing Excessive Tip Wear • Spray should be atomized (evenly distributed, no gaps at edges). Start at low pressure set- ting, increase pressure a little at a time until you 1. Engage trigger lock. see a good spray pattern, without tails.
  • Page 13: Unclogging Spray Tip

    Setup Unclogging Spray Tip 4. Unlock trigger lock. Pull ti8922a trigger to clear clog. ti8909a To avoid fluid splashback: (SG10) (SG20) • Never pull gun trigger when arrow-shaped han- dle is between SPRAY and UNCLOG positions. 5. When obstruction is •...
  • Page 14: Tip Selection

    Setup Tip Selection Selecting Tip Hole Size Tips come in a variety of hole sizes for spraying a • Maximum tip hole sizes supported by the range of fluids. Your sprayer includes an 0.015 in sprayer: (0.38 mm) tip for use in most spraying applications. –...
  • Page 15: Understanding Tip Number

    Setup Understanding Tip Number Reversible Tip Selection Chart The last three digits of tip number (i.e.: 221413) Fan Width 12 in. contain information about hole size and fan width Part (305 mm) from on surface when gun is held 12 in. (30.5 cm) from surface Hole Size surface being sprayed.
  • Page 16: Getting Started With Basic Techniques

    Getting Started With Basic Techniques Getting Started With Basic Techniques Triggering Gun Use a piece of scrap cardboard to practice these basic spraying techniques before you begin spray- Pull trigger after starting stroke. Release trigger ing the surface. before end of stroke. Gun must be moving when •...
  • Page 17: Shutdown And Cleaning

    Shutdown and Cleaning Shutdown and Cleaning Pail Flushing • For short term shutdown periods (over- 6. Place prime tube in waste night to two days) refer to Short Term Stor- pail. age, page 22. • For flushing after spraying oil-based coat- ings, use compatible oil-based flushing fluid or mineral spirits.
  • Page 18 Shutdown and Cleaning 13. While continuing to trigger Step 12 is for returning paint in hose back to gun, quickly move gun to paint pail. One 50-ft hose holds approximately redirect spray into waste 1-quart (1-liter) of paint. pail. Continue triggering gun into waste pail until 12.
  • Page 19: Power Flush

    Shutdown and Cleaning Power Flush Power flushing is a faster method of flushing. It can 10. Unscrew inlet screen from suction only be used after spraying water-based coatings. tube. Place inlet screen in waste pail. 1. Relieve pressure, page 9. 2.
  • Page 20 Shutdown and Cleaning 18. Stop triggering Step 16 is for returning paint in hose back to gun. Engage paint pail. One 50-ft (15-m) hose holds approx- trigger lock. ti8923a imately 1-quart (1-liter) of paint. ti8908a SG10 SG20 16. To preserve paint 19.
  • Page 21: Cleaning Gun

    Shutdown and Cleaning ™ Cleaning InstaClean Fluid 4. Tighten outlet fitting and Filter (ProX Sprayers Only) reconnect hose (a) to sprayer. Use two wrenches to tighten The InstaClean Fluid Filter prevents particles from securely. entering paint hose. After each use, remove and clean it to insure peak performance.
  • Page 22: Short-Term Storage

    Storage Storage Long Term Storage Short Term Storage (more than 2 days) (up to 2 days) • Always circulate Pump Armor storage fluid 1. Relieve pressure, page 9. through system after cleaning. Water left in sprayer will corrode and damage pump. 2.
  • Page 23: Stowing Sprayer

    Storage Stowing Sprayer CAUTION • Before storing sprayer make sure all water is Fold-n-Store Storage drained out of sprayer and hoses. The sprayer cart can be folded for convenient and • Do not allow water to freeze in sprayer or hose. compact storage.
  • Page 24 Storage Unfolding the Sprayer (ProX Sprayers Only) 1. If folded for compact, Storage Options (ProX Sprayers Only) shelf storage, unfold • The folded sprayer can be handle (a) and align stored on a wall as as shown. shown. 2. Tighten wingnuts (b). ti9675a ti9677a •...
  • Page 25: Maintenance And Service

    • Replace pump packings at first sign of leaking or addi- tional damage could occur. • Purchase a pump repair kit ti9355a and install according to instructions provided with kit. ti9356a • Consult a Graco/M AGNUM authorized service center. 312001G...
  • Page 26: Troubleshooting

    Troubleshooting Troubleshooting Check everything in this Troubleshooting Table before you bring the sprayer to a Graco/M AGNUM authorized service center. Problem Cause Solution Power switch is on and sprayer is Pressure is set at zero pressure. Turn pressure control knob clock- plugged in, but motor does not wise to increase pressure setting.
  • Page 27 Turn power switch ON and listen for “tap” in pump. If you do not hear “tap”, AutoPrime is dam- aged. Take sprayer to Graco/M authorized service center. Inlet valve check ball or seat is Remove inlet fitting. Clean or dirty replace ball and seat.
  • Page 28 Tighten suction tube connection. Inspect for cracks or vacuum leaks. If cracked or damaged, replace suction tube. Prime/Spray Valve is worn or Take sprayer to Graco/M AGNUM obstructed with debris. authorized service center. Pump check ball is stuck. Read Pump does not prime sec- tion in Troubleshooting, page 27.
  • Page 29 Tighten suction tube connection. Inspect for cracks or vacuum leaks. Prime/Spray valve is plugged. Clean/replace prime tube as nec- essary. Take sprayer to Graco/M authorized ser- AGNUM vice center if valve is plugged. Spray tip is clogged. Unclog spray tip, page 13.
  • Page 30 Choose tip with larger hole size. Choose tip with narrower fan. Make sure gun is close enough to surface. Fan pattern varies dramatically Pressure control switch is worn Take sprayer to Graco/M AGNUM while spraying. and causing excessive pressure authorized service center. variation.
  • Page 31: Technical Data

    Technical Data Technical Data AGNUM AGNUM Working pressure range 0-2800 psi (0-19 MPa, 0-193 bar) 0-3000 psi (0-21 MPa, 0-207 bar) Electric motor 6.0A (open frame, universal) 6.0A (open frame, universal) Operating horsepower Maximum delivery (with tip) 0.24 gpm (0.91 lpm) 0.31 gpm (1.17 lpm) Paint hose 1/4 in.
  • Page 32 Technical Data ProX7 ProX9 AGNUM AGNUM Working pressure range 0-3000 psi (0-21 MPa, 0-207 bar) 0-3000 psi (0-21 MPa, 0-207 bar) Electric motor 5.8A (open frame, 9.4A (open frame, permanent magnet DC) permanent magnet DC) Operating horsepower Maximum delivery (with tip) 0.34 gpm (1.29 lpm) 0.38 gpm (1.44 lpm) Paint hose...
  • Page 33 Notes Notes 312001G...
  • Page 34: Graco Standard Warranty

    With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective.

This manual is also suitable for:

Magnum prox7Magnum x7Magnum prox9