. 14. Clean Air Cap and Fluid Nozzle
IG

Check for Fluid Leakage

If any fluid leakage from the gun is detected, stop
spraying immediately. Fluid leakage into the gun
shroud could cause fire or explosion and result in
serious injury and property damage.
YY
ZZ
F
. 15. Check for Fluid Leakage
IG
313227E
TI13431a
7
4
TI13429a
To reduce the risk of an injury, follow the Pressure
Relief Procedure on page 15 when you stop
spraying and whenever you are instructed to relieve
the pressure.
During operation, periodically check the manifold
exhaust tube (YY) and both ends of the gun shroud (ZZ)
for the presence of fluid. See F
areas indicates leakage into the shroud, which could be
caused by leaks at the fluid tube connections or fluid
packing leakage.
If fluid is seen in these areas, stop spraying immedi-
ately. Relieve the pressure, then remove the gun for
repair.