Avaya S8730 Maintaining Manual page 42

For modular messaging
Hide thumbs Also See for S8730:
Table of Contents

Advertisement

Adding and replacing a hard drive
Online/activity
LED (green)
On, off, or flashing
On, off, or flashing
On
On
Flashing regularly
(1 Hz)
Flashing regularly
(1 Hz)
Flashing
irregularly
Flashing
irregularly
Off
42
Maintaining the Avaya S8730 Server for Modular Messaging
Fault/UID LED
(amber/blue)
Alternating amber
and blue
Steadily blue
Amber, flashing
regularly (1 Hz)
Off
Amber, flashing
regularly (1 Hz)
Off
Amber flashing
regularly (1 Hz)
Off
Steadily amber
Description
The drive has failed or a predictive
failure alert has been received for this
drive.
The drive is operating normally.
A predictive failure alert has been
received for this drive; replace the drive
as soon as possible.
The drive is online, but is not currently
active.
Caution:
Do not remove the drive; removing a
drive might terminate the current
operation and/or cause data loss.
The drive is part of an array that is
undergoing capacity expansion or
stripe mitigation, but a predictive failure
alert has been received for this drive. To
minimize the risk of data loss, do not
replace the drive until the expansion or
migration is complete.
Caution:
Do not remove the drive; removing a
drive might terminate the current
operation and/or cause data loss.
The drive is rebuilding or is part of an
array that is undergoing capacity
expansion or stripe mitigation.
The drive is active, but a predictive
failure alert has been received for this
drive; replace the drive as soon as
possible.
The drive is active and is operating
normally.
A critical fault condition has been
identified for this drive and the controller
has placed it offline. Replace the drive
as soon as possible.
June 2009

Advertisement

Table of Contents
loading

Table of Contents