Expansion Enclosure Service Procedures; Add A Drive In A 25-Drive Expansion Enclosure; Removing The Front Bezel - Dell EMC PowerStore T Installation And Service Manual

Table of Contents

Advertisement

Expansion enclosure service procedures

The expansion enclosure contains customer-replaceable components. Follow these procedures to safely replace a failed component.
NOTE:
Review the information in
Topics:

Add a drive in a 25-drive expansion enclosure

Replace a faulted drive in a 25-drive expansion enclosure
Replace a link control card in a 25-drive expansion enclosure
Replace a power/cooling module in a 25-drive expansion enclosure
Add a drive in a 25-drive expansion enclosure
Take the following actions to add a new drive to a 25-drive expansion enclosure.

Removing the front bezel

About this task
NOTE:
Remove the front bezel of the expansion enclosure to gain access to the drives. The bezel is required for EMI
compliance when the enclosure is powered up. Remove it only to replace or add a drive.
Steps
1. If the bezel has a lock, insert the key that shipped with your enclosure into the lock, and turn the key to unlock the bezel.
2. Press the two latch buttons on the bezel surface to release the bezel from the cabinet.
3. Pull the bezel off the cabinet, and put it on a clean, static-free surface.
Figure 117. Removing the front bezel
82
Expansion enclosure service procedures
Safety precautions for handling replaceable units
before handling replaceable parts.
CL5261
3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Emc powerstore x

Table of Contents