Faulted parts appear in red in the image of the system, and report a status of Faulted in the State field.
Embedded module LEDs
Use the fault LEDs to identify the faulted part.
Figure 30. Embedded module LEDs
Table 2. Embedded module LEDs
LED
Embedded module fault
Ethernet port link
Ethernet port activity
SAS port and activity link
Port link
Node fault
Node power
Unsafe to remove
Power down the node
Power down the node as described in
Remove a faulted embedded module
Steps
1. Label and disconnect all cables that are attached to the embedded module.
Location
Power control
procedures.
State
Description
Amber
Embedded module has faulted.
Off
No fault has occurred, normal operation.
Green
Link established.
Off
No link established.
Amber blinking
Port activity.
Off
No port activity.
Blue
SAS port link is up.
Off
No link established.
Green
Link up with high speed.
Amber
Link up with degraded speed.
Off
Link down.
Amber
Fault has occurred in the node or one of its
components.
Off
No fault has occurred. Normal operation.
Green
Node is on (main power).
Off
Node is off.
White
Do not remove the node. Improper removal
could cause data loss.
Off
Safe to remove the node when the node
has been properly prepared.
Base enclosure service procedures
35