LED
Node power
Unsafe to remove
Power down the node
Power down the node as described in
Remove an embedded module
Steps
1. Label and disconnect all cables that are attached to the embedded module.
CAUTION:
Do not pull the node from the base enclosure. Pulling the node from the base enclosure disrupts the
system cache.
2. Push the orange tab on the embedded module to release the lever.
Location
Power control
procedures.
State
Description
Blue and amber
Node in Service Mode.
alternating at one
second intervals
Off
No fault has occurred, normal operation.
Green
Node is on (main power).
Green blinking
Node is initializing a serial over LAN session
(Standby Mode).
Off
Node is off.
White
Do not remove the node. Improper removal
could cause data loss.
Off
Safe to remove the embedded module when
the embedded module has been properly
prepared.
Base enclosure service procedures