Description
3.2 Structure
3.2.2

Nameplate layout

Example of manufacturer nameplate
Example of explosion protection nameplate
For technical data and temperature classes, see certificate / Operating Instructions
TÜV 17 ATEX 205947 X / IECEx TUN 17.0023 X
II 2 G
Ex ia IIC T6/T4 Gb
II 2 D
Ex ia IIIC T130°C Db
II 3 G
Ex ec IIC T6/T4 Gc
Cl I Zn 1 AEx ib IIC Gb / Cl I Zn 1 Ex ib IIC Gb
IS Cl I, II, III Div 1 Gp A-G
FM17US0053X
Cl I Zn 2 AEx nA IIC Gc / Cl I Zn 2 Ex nA IIC Gc
Zn 21 AEx tb IIIC T100°C Db / Zn 21 Ex tb IIIC T100°C Db
For installations in U.S.A. and Canada:
Install per control drawing A5E00065622D Rev.16
CSA18CA70166848X
-30°C ≤ Ta ≤
Approvals
ATEX/IECEx marking for hazardous area
26
SIPART PS2 i/p Positioner
6 D R 5 0 2 1 - 0 K * 0 2 - 0 A A 0
-Z S10;S11;S12;S13;S14;S15;S16
-
-
Iw=4...20mA
Siemens AG, DE-76181 Karlsruhe
www.siemens.com/sipartps2
MADE IN FRANCE
Manufacturer
Degree of protection
Observe the operating instructions
Conformity with country-specific directives
Built-in option modules
QR code to the mobile website with device-spe‐
cific product information
Serial number
/ BRA-18-GE-0006 X
II 3 G
Ex ic IIC T6/T4 Gc
II 2 D
Ex tb IIIC T100°C Db
-
-
Zn 21 AEx ib IIIC, T130°C Db / Zn 21 Ex ib IIIC, T130°C Db
-
NI Cl I Div 2 Gp A-D
DIP Cl II, III Div 1 Gp E-G
-
+60°C(T6)/80°C(T4)
IP66 / Type 4X
<SW: x.xx.xx(2)>
-
p = 1.4 ... 7 bar
-
<HW: x.xx.xx(2)>
S/N: ARR P3-123456
S/N: ARR P3-123456
BRA-18-GE-0006 X /
BRA-18-GE-0006 X /
TÜV 17 ATEX 205947 X / IECEx TUN 17.0023 X
TÜV 17 ATEX 205947 X / IECEx TUN 17.0023 X
II 2 G
II 2 G
II 3 G
II 3 G
II 2 D
II 2 D
II 2 D
II 2 D
II 3 G
II 3 G
Cl I Zn 1 AEx ib IIC Gb / Cl I Zn 1 Ex ib IIC Gb
Cl I Zn 1 AEx ib IIC Gb / Cl I Zn 1 Ex ib IIC Gb
Zn 21 AEx ib IIIC, T130°C Db / Zn 21 Ex ib IIIC, T130°C
Zn 21 AEx ib IIIC, T130°C Db / Zn 21 Ex ib IIIC, T130°C
IS Cl I, II, III Div 1 Gp A-G
IS Cl I, II, III Div 1 Gp A-G
-
-
FM17US0360X
FM17US0053X
Cl I Zn 2 AEx nA IIC Gc / Cl I Zn 2 Ex nA IIC Gc
Cl I Zn 2 AEx nA IIC Gc / Cl I Zn 2 Ex nA IIC Gc
NI Cl I Div 2 Gp A-D
NI Cl I Div 2 Gp A-D
-
-
Zn 21 AEx tb IIIC T100°C Db / Zn 21 Ex tb IIIC T100°C Db
Zn 21 AEx tb IIIC T100°C Db / Zn 21 Ex tb IIIC T100°C Db
DIP Cl II, III Div 1 Gp E-G
DIP Cl II, III Div 1 Gp E-G
CSA18CA70166848X
CSA18CA70166848X
GYJ18.1168X
-
13-KB4BO-0369X
13-KB4BO-0369X
13-KB4BO-0369X
-
-
15-AV4BO-0297
-
For technical data and temperature classes, see certificate
For technical data and temperature classes, see certificate
FM/CSA marking for hazardous area
Permissible ambient temperature for operation in
hazardous areas
Operating Instructions, 11/2019, A5E00074631-AE
-
DIO
-
NCS
-
KCC-REM-S49
SIPART PS2
-
-
PROCESS CONTROL
EQUIPMENT
-
Imax=100mA
-
Umax=35VDC
S/N: N1A6101234567
-
-
Supply pressure PZ
Software version and hardware version
Country of origin
Supply voltage
Ordering supplement (Order code)
Article number
Product name
0518
0518
Ex ia IIC T6/T4 Gb
Ex ia IIC T6/T4 Gb
Ex ic IIC T6/T4 Gc
Ex ic IIC T6/T4 Gc
Ex ia IIIC T130°C Db
Ex ia IIIC T130°C Db
Ex tb IIIC T100°C Db
Ex tb IIIC T100°C Db
Ex ec IIC T6/T4 Gc
Ex ec IIC T6/T4 Gc
-
-
GYJ18.1168X
GYJ18.1168X
-
-
-30°C ≤ Ta ≤ +60°C(T6)/80°C(T4)
-30°C ≤ Ta ≤ +60°C(T6)/80°C(T4)
/ Operating Instructions
/ Operating Instructions
-
-
SIPART PS2 with 4 to 20 mA/HART
-
-
ILS
MLS
X
-
AIM
AOM