DTC
Message on
Number
GCON LCD
P001:PWR FAULT
P001
SW PWR1:BAT-
P003:PWR FAULT
P003
SW PWR1:BAT+
P004:DEVICEFAULT
P004
HORN:BAT-
P005:DEVICEFAULT
P005
HORN:OPEN
P006:DEVICEFAULT
P006
HORN:BAT+
P007:DEVICEFAULT
P007
GCON ALARM:BAT-
P009:DEVICEFAULT
P009
GCON ALARM:BAT+
P013:PWR FAULT
P013
PCON PWRET:BAT-
P015:PWR FAULT
P015
PCON PWRET:BAT+
018:PWR FAULT
P018
PCON POWER:BAT-
018:PWR FAULT
P019
PCON POWER:BAT+
88
Problem
Description
Short circuit of the switched power #1
circuit to battery negative.
Short circuit of the switched power #1
circuit to battery positive.
Short circuit of the automotive horn circuit to
battery negative.
Open circuit of the automotive horn circuit.
Short circuit of the automotive horn circuit to
battery positive.
Short circuit of the GCON alarm circuit to
battery negative.
Short circuit of the GCON alarm circuit to
battery positive.
Short circuit of the PCON power return circuit
to battery negative.
Short circuit of the PCON power return circuit
to battery positive.
Short circuit of the PCON power circuit to
battery negative.
Short circuit of the PCON power circuit to
battery positive.
GS-2646 AV • GS-2646 AV35
Possible
Causes
• Short circuit in switched power #1, down limit
switch, pothole limit switch, digital tilt switch
harness
• GCON ECM
• Short circuit in switched power #1, down limit
switch, pothole limit switch, digital tilt switch
harness
• GCON ECM
• Short circuit in automotive horn harness
• Automotive horn short circuit
• GCON ECM
• Open circuit in automotive horn harness
• Automotive horn open circuit
• GCON ECM
• Short circuit in automotive horn harness
• Automotive horn short circuit
• GCON ECM
• Short circuit in GCON alarm harness
• GCON alarm short circuit
• GCON ECM
• Short circuit in GCON alarm harness
• GCON alarm short circuit
• GCON ECM
• Short circuit in PCON power return harness
• GCON ECM
• Short circuit in PCON power return harness
• GCON ECM
• Short circuit in PCON power harness
• GCON ECM
• Short circuit in PCON power harness
• GCON ECM
September 2016
Failure
Mode
All functions
inhibited.
All functions
inhibited.
Automotive horn
inhibited.
Automotive horn
inhibited.
Automotive horn
inhibited.
GCON alarm
inhibited.
GCON alarm
inhibited.
All functions
inhibited.
All functions
inhibited.
All functions
inhibited.
All functions
inhibited.
Part No. 1272218