Manifolds; Function Manifold Components - Genie GS-2646AV Service And Repair Manual

Table of Contents

Advertisement

Service and Repair Manual

Manifolds

5-1

Function Manifold Components

The function manifold is mounted behind an inspection door, at the ground control side of the machine.
Index No. Description
Coil Nut (item AC)
Coil Nut (items AE, AG and AI)
1
Diagnostic nipple
2
Relief Valve, 3700 psi / 255 bar maximum
3
Solenoid valve, 3 position 4 way
4
Check disc
5
Solenoid valve, 2 position 4 way
6
Relief valve
7
Solenoid valve, 3 position 5 way
8
Flow regulator and relief valve,
0.75 gpm / 2.8 L/min, 1500 psi / 103 bar
9
Solenoid valve, 2 position 4 way
10
Relief valve
How to Install a Valve Cartridge
1
Dip the cartridge in clean oil to lube the O-rings.
2
Screw the cartridge in by hand until the top O-ring is met, then torque to specifications.
3
If required, install the valve coil(s) onto the valve stem. Install the coil nut onto the valve stem and
torque to specifications.
46
Schematic
Item
AA
AB
AC
AD
AE
AF
AG
AH
AI
AJ
GS-2646 AV • GS-2646 AV35
Function
Testing
System relief
Steer left/right
Steer circuit
Drive speed select circuit
Brake release
Drive forward/reverse
Steer circuit
Platform up
Lift relief
September 2016
Torque
4-5 ft-lbs / 5-7 Nm
5-7 ft-lbs / 7-9 Nm
20 ft-lbs / 27 Nm
25 ft-lbs / 34 Nm
18 ft-lbs / 24 Nm
25 ft-lbs / 34 Nm
20 ft-lbs / 27 Nm
25 ft-lbs / 34 Nm
26 ft-lbs / 35 Nm
25 ft-lbs / 34 Nm
20 ft-lbs / 27 Nm
Part No. 1272218