Connect the lines

acceptable cross-section (di-
ameter)
max. number of wires per
terminal contact
 Further wires have to be connected via auxiliar terminals!
!
 Use only connecting lines with the same diameter within one termi-
nal contact.
 Guide the connection lines (without spare
cable loop) in the top shell directly to the
terminals.
 Thus, the top shell can be snapped-on
without any problems and the connection
lines will not get clamped.
 Connect the lines according to the labelling.

Terminating resistor CAI2000

In delivery state the terminating resistor is in-
active:
 The jumper bridges the upper two contacts.
If the device is to be installed at the end of a
cable chain, the terminating resistor must be
activated.
 The jumper bridges the lower two contacts.
0.08 ... 0.82 mm
each 2 x 0.8 mm, 3 x 0.6 mm
2
(Ø 0.32 ... 1.0 mm)
V2
V1
M
P
E
b
a