Wiring diagram: examples for connecting the relay
Set basic function or standard function at the mode switch
 Select the position of the DIP switch 2 according to your system.
 When starting or restarting the front-door station, the setting is read out. After starting
the system, the DIP switches 3 and 4 have to be switched to position ON. If not, newly
set values will be overwritten with standard values when restarting the system again.
factory setting

Fix the front-door station in the flush-mount box

 Fix the front-door station with the included hexagon socket screws through the attache-
ment holes on the studs in the flush-mount box.
 Ensure that the screws are not over tightened. The housing of the flush-mount box
could deform and front plate and name plate glass can not be installed resp. removed.
TCS TürControlSysteme AG, www.tcsag.de
TCS Hotline • Mail: hotline@tcsag.de
1
not assigned
ON: normal
4
OFF: standard address 192.168.1.250, load net settings
ON: normal
3
OFF: load parameter factory setting
ON: system peer to peer
2
OFF: system SIP server
9
direct connection with AVU94x0x
Subject to technical changes.
PI_AVU940x0-uk