XEVO 125 Euro 3
Cut the clamp on the transmission
crankcase duct; after that, disconnect
the pipe connected to the air intake on
the chassis.
Disconnect the electric connector link-
ing the magneto flywheel to the vehicle
cable harness.
Remove the starter motor electrical
connections acting on the two screws.
Remove the footrest and the left side
fairing; move the lower central cover
slightly to the outside and remove the
three screws fixing the supporting plate
of the swinging arm buffer.
Remove the buffer sealing seeger ring
and remove the supporting plate of the
swinging arm buffer.
Support the vehicle adequately with
the jack. Remove the engine-swinging
arm fixing pin by acting on the nut and
the pin head as shown in the figure.
The engine is now free.
Engine from vehicle
ENG VE - 5