On-Board FastRegen Control Module Programming and Operation Instructions
Table B-1: On-Board Module RS-232 Commands (Continued)
Command
S
P/N 8040406
Parameter
1 - 3
Send back various status indicators.
Status 1
01H = Pump ON
02H = Rough valve ON
04H = Purge valve ON
08H = Cryo TC ON
10H = Aux TC ON
20H = A result of 0 means that there was a power failure. The
Status 2
01H = Setpoint 1 ON
02H = Setpoint 2 ON
08H = First stage temperature control ON
Status 3
01H = Pump phase 1 check
02H = Pump phase 2 check
Description
bit is reset to 1 after this query.
-