. Technical data

Dimensions of
215 x 275 x 190
housing:
Assembling height:
vertically at the wall, min. at a height of
100 mm
Power supply via
400 V, 50 / 60 Hz; - max. power input 2200 W
L1, L2, L3, N, PE:
- 3.2 A; duty cycle 60% for a maximum run-
ning time of 120 s
Protection:
10 A K-characteristic
Own consumption of
max. 250 mA
control:
Control voltage:
24 V DC, max. 250 mA; protected by self-reset-
ting safety for external sensors
Control inputs:
24 V DC, all inputs are to be connected free of
potential, min. signal time for incoming control
command >100 ms.
Control outputs:
24 V DC, max. 250 mA
RS485 A and B
Only for electronic final switch.
RS485 level, closed with 120 Ω
Safety chain /
all input connections must be potential-free;
Emergency
if the safety circuit is interrupted, no further
shutdown:
electrically powered movement of the drive is
possible,
not even in deadman mode.
Input safety bar:
For electrical safety bars with 8,2 kΩ, moving
loads and dynamic optic systems.
Relays output:
If inductive loads are switched to (e.g.: relays
or breaks), so these must be equipped with
corresponding interference measures (recovery
diode, varistores, RC modules).
Operating contact free of potential,
min. 10 mA; max. 230V AC / 4A
Contacts used once for power switch are not
able to switch mini power anymore.
Temperature range:
Operation:
Storage:
Air humidity:
to 80% non condensing
Vibrations:
Assembling works with less vibration, e.g. at a
masonned wall
Type of protection:
IP 54
Weight:
about 1,8 kg
-10 °C ... +45 °C
-25 °C ... +70 °C
CS 300 Gate Controls / Rev. 5.3 – 
GB